The check that cannot see the error
Every analysis prints a global equilibrium residual, and it is the first thing anybody looks at. It catches a lost restraint and a load entered in the wrong unit immediately. It is structurally incapable of catching a member whose stiffness is wrong by a factor of ten, because the wrong answer is still in equilibrium with the same loads.
Stiffer than the model said
Measured natural frequencies of finished buildings come out between ten and sixty per cent above the values computed for them, consistently and in one direction only. Nothing on the list of reasons is a modelling error: every one is a real source of stiffness deliberately left out — and leaving stiffness out is conservative for deflection and unconservative for vibration.
Named alongside it
The objects these essays reach for when they reach for this one.
StiffnessCalibrationCompatibilityComposite actionDampingDeflectionDegrees of freedomDeterminacyEquilibriumFloor vibrationFootfallFree body