The load must go somewhere — page 13
The corners the pressure pulls up
Replace a uniform pressure on a beam element by its work-equivalent nodal loads and the ends acquire couples the resultant cannot see. Do the same on an eight-node plate element and the corners acquire forces pointing the wrong way: a pressure pushing down is represented by the corners being pulled up, a twelfth of the load each. It is correct, it is the vector that makes the solution the best one available, and it is the reason a printout of nodal forces is not a picture of where a load goes.
The pier that carries only the difference
A stressed ribbon continued over a pier pulls on it from both sides, and under its own weight the two pulls cancel. Load one span and they do not: the pier is asked for the difference, nearly ten meganewtons for a crowd on one of two hundred-metre spans. Whether it gives it depends on its stiffness against a number the ribbon supplies itself, and whatever the pier does not carry, the ribbon turns into movement — a third of a metre of extra sag in the loaded span and a fifth of a metre of rise in the empty one.
The pipe held at every floor
A riser runs the height of a building and is fixed at every floor, so each of its supports moves with a different floor. The floor spectrum prices the pipe's inertia, and for a pipe anchored at every floor the inertia is nearly irrelevant: the drift puts 131 N/mm² into a 100 mm riser at two thirds of a per cent, thirty times its inertia, and passes yield at 200 mm. Guide the same pipe instead of anchoring it and the drift almost vanishes — the pipe then feels only how much the drift changes from one storey to the next.
The ground that arrives after the weight
A block's resistance to tipping on ground that can yield is a parabola in its weight, with its peak at half of what the ground can bear. On soft clay the ground's capacity is not fixed: it grows as the clay drains under the weight, and it grows years after the weight has arrived. A tower on such ground is at its weakest on the day it is finished — 1.33 against the 1.93 it will have once the clay has drained — and a silo filled in a week walks over the top of the parabola and down the far side, which is the other way a structure can be built.
The truss whose forces follow its sections
In a determinate truss each member's force is fixed before its section is chosen, so sizing for strength and sizing for stiffness can be done in either order. Put a counter-diagonal in every panel and they cannot. The fully stressed design becomes an iteration that starves some counters to nothing and keeps others, lands on a different truss from every start, and — whichever it lands on — weighs the same and deflects the same. Then enlarge one group of members to stiffen it, and a vertical nobody touched is overloaded by 58 per cent.
The factor of two belongs to one mode
A member that fails suddenly hands its force to the structure around it all at once, and the convention is to double the static answer: a load applied suddenly to a spring overshoots to twice its static deflection. A truss is not one spring. Take a diagonal out of a counter-braced truss in an instant and some members swing to three times their change of force, one swings the wrong way first, and a bottom chord whose force does not change at all passes through half as much again as it carries — because every mode overshoots by two, at its own time, and a member is a sum of modes.
The layer a pile feels
A pile pushed sideways in uniform ground has one characteristic length, the fifth root of its stiffness over the ground's, and every answer is a multiple of it. Put a soft layer over stiff ground and that length stops existing. The head feels the top of the ground in proportion to the square of its own deflection, so an average weighted that way gets the head deflection within eight per cent. It gets the moment a quarter too low: with soft ground two characteristic lengths thick over stiff, the pile bends harder than it would in either ground alone, and the peak sits where the stiff ground takes hold.
The ground that never quite gives way
On a bed of springs capped at the ground's bearing limit, a block pushed sideways tips at a definite push, below the limit the rigid-plastic parabola gives. Real ground is curved: it softens all the way to its limit and never quite reaches it. On such ground the block has no tipping push of its own. Its resistance creeps toward the limit, and the peak it does have is made by its own weight leaning with it — 14 per cent below the limit with the weight 5 m up, nearly at it with the weight at the base, where the lean simply runs away.
A deck is a spring, not a wall
An open-section beam loaded off its shear centre twists, and the usual reassurance is that the deck fastened to its top flange will stop it. The deck resists the flange's rotation with a stiffness per metre of span, and that stiffness has to be compared with the beam's own. On an 8 m beam a screwed deck of ordinary stiffness removes a third of the twist; on a 16 m beam the same deck removes three quarters, because the beam's torsional stiffness falls with the square of its span and the deck's does not.
The pull that Johansen left out
Johansen's mechanisms treat a timber fastener as a beam in a bed of crushing wood, bent and pushed sideways and nothing else. A real fastener that tilts across the joint is also pulled along its own axis, and if a washer or a thread resists the pull, it clamps the two members together and adds to what the joint can carry. The addition is a quarter of the axial resistance, it goes only to the modes in which the fastener tilts, and it is capped by fastener type — nothing for a dowel, a quarter for a bolt, all of it for a screw — which is how a screw keeps gaining strength past the thickness at which Johansen's capacity stops.
A failed slope gives a line, not a soil
A slope that has slipped is the one full-scale strength test geotechnics ever gets, and the standard way to read it is to set its factor of safety to one and solve for the soil. One equation cannot give two strengths. What it gives is a line of cohesions and friction angles, every one of which fails the slope exactly, and the repair designed on one point of that line can be worth a factor of 1.07 or of 1.51. The slip itself says which point: each soil on the line fails along a different surface, and the depth of the scar is the second equation.
The panel that gravity leaves empty
A corner joint's panel carries the difference between a beam's flange couple and half a column's shear, and full gravity load is what makes that large. An interior joint has a beam on each side, and under full gravity their two couples cancel: the panel between them carries nothing at all, in the load case that sizes every member around it. It fills under the two loads that are not symmetric. A pattern load hands it one beam's moment, and sway hands it two beams' moments turning the same way. Together they put more shear through it than through any exterior joint, in a combination that governs no member.
Loaded twice over before it is a month old
A concrete floor in a building going up a storey a week carries, in its first weeks, the wet weight of the floors being cast above it, handed down through the props. By Grundy and Kabaila's arithmetic that is twice its own weight on a single level of shores, and more with more levels — 2.25 on two, 2.37 on three — because every prop that carried wet concrete passes its load down the stack. The same props put in after the formwork is struck carry nothing until something new arrives, and the peak falls to 1.5, 1.33, 1.25. The heaviest day of a floor's life is decided by when its props went in, not how many there are.
The fixed base the bolts decide
A column base drawn as fixed is a spring, and the component method says what it is made of: the grout squeezed under the flange, the plate bending under the bolt row, and the anchor bolts stretching over their free length. For a 500 mm plate on two M24 bolts the bolts are three fifths of its flexibility, so the base comes out at nine times the column's EI/L — under a third of what EN 1993-1-8 calls rigid — and no thickness of plate can lift it above fifteen. Leave the bolts free in sleeves for erection tolerance and it falls to five. The frame on it drifts 28 per cent more than a fixed-based one and buckles at 83 per cent of the load.
The pressure the roller leaves behind
A retaining wall is designed for the pressure of the soil it holds, a triangle growing with depth. The soil behind most walls was not tipped there. It was placed in layers and rolled, and each pass of the roller pushed the soil sideways against the wall harder than the soil's own weight ever could, and left most of that push locked in when it moved on. Behind a 3 m wall compacted by an ordinary vibrating roller the locked-in pressure is a constant 28 kPa from half a metre down, the thrust two and a half times the active triangle's and the moment at the base three and a half.
The weight that bends a rib it cannot bend
A parabolic rib carries its own uniform dead load as pure thrust, with no bending in it at all. Put a live load on half the span and the rib bends in the shape of its own buckling mode from the first kilonewton, and the whole thrust, most of it from the dead load, multiplies that bending. The rib never reaches its buckling load. It yields well short of it, at a load its first-order check says it can carry.
Rigid by one code and not by the other
A floor plate between shear walls shares its storey force out in proportions that move continuously with its stiffness, from a continuous beam's to a rigid body's. The codes put it in one of two boxes and use a different model in each. ASCE 7 and EN 1998-1 draw their boxes' edges a hundred times apart in plate stiffness, each at a point where its own licensed model already misstates the middle wall by about a tenth — and an ordinary 200 mm slab sits in the gap between them.
The springings that make shortening worse
Fixing an arch at its springings is the stiffer, cheaper and usual way to build one in concrete, and it makes the arch six times as sensitive to its own shortening. The thrust it loses acts at the elastic centre, two thirds of the way up, so the moment lands at the springings as well as the crown, twice as large and the other way round — at the section the fixed arch is designed at, not away from it.
The perimeter whose middle is not the column's
At an edge column the slab's own edge cuts the control perimeter, and what is left has its centroid 363 mm inside the column's centre. The slab's end moment moves the shear's resultant inward too, by a distance that grows with the end span. What twists the perimeter is the gap between the two: nothing at a 5 m end span, enough by 7.2 m to put the check at 1.23 of its resistance where the 1.4 shortcut reads 0.97. And a bigger column makes it worse.
The abutment that spreads before it turns
A fixed arch is fixed only if its abutments hold still, and they have two ways not to. Turning releases the springing moment, but slowly: an abutment has to be a hundred times the rib's EI/L to hold nine tenths of it, and a footing on stiff clay under a slender concrete rib already is. Spreading does the opposite. The rib's own shortening is worth 13.6 mm of spread, so an abutment that gives 7 mm a side under the thrust doubles every secondary moment in the arch — and a footing on dense sand gives 8.
The screw that is pulled instead of bent
A screw square to a timber joint resists slip by bending, and its thread is engaged only when it has tilted far enough to be pulled. Lean the same screw to 45 degrees and the slip pulls it from the first millimetre. An 8 mm screw through two 100 mm members goes from 5.9 kN to 13.4, reached after 2.2 mm of slip instead of more than twelve, and the bending that Johansen's model is about becomes an eighth of the joint. The price is a joint that holds one way better than the other.
The floors that fill up together
A column may be designed for less than the sum of its floors' imposed loads because the floors do not reach their worst day together — an argument that assumes each floor's load is independent of every other's. Let any two floors be correlated, and the reduction the averaging can pay for shrinks, and stops shrinking at a higher floor. At a correlation of 0.16 that floor reaches the 0.7 the storey rule falls to. One tenant on five floors halves what twenty floors can average away.
The storey above the core decides
A building whose bending core runs to the roof shares one sway mode between its core and its frame, and the storey-by-storey stability check reads it wrongly twice. Stop the core five storeys short and the check becomes exact: the first storey of bare frame above the core reads the building's own critical factor to three figures, because the whole building buckles there and nowhere else. The check stays wrong below the core, and it goes wrong again when the frame above is more than about twice as stiff.
The web that moves the centre and not the twist
A thin plate closing a channel into a box changes its torsion at once and its shear centre hardly at all. An interior web dividing a box into two cells does the reverse. Off the middle of a 600 mm box, a web as thick as the walls takes 38 per cent of the vertical shear — more than either outer web — and pulls the shear centre 27 mm toward itself, while the torsion constant changes by less than one per cent. The two walls are the same kind of wall; what differs is which flow they are part of.