A downward pressure that pulls the corners up. The nodal forces that do the same work as a uniform pressure on one eight-node serendipity quadrilateral, as fractions of the whole load, each node's share being the integral of its shape function over the element. The shares are −1/12, −1/12, −1/12, −1/12, 1/3, 1/3, 1/3, 1/3 at its eight nodes, adding up to one. The four corner forces are negative: the pressure pushes down and the work-equivalent forces at the corners pull up. Equilibrium

The corners the pressure pulls up

Replace a uniform pressure on a beam element by its work-equivalent nodal loads and the ends acquire couples the resultant cannot see. Do the same on an eight-node plate element and the corners acquire forces pointing the wrong way: a pressure pushing down is represented by the corners being pulled up, a twelfth of the load each. It is correct, it is the vector that makes the solution the best one available, and it is the reason a printout of nodal forces is not a picture of where a load goes.

A load on one span moves the other. The change in level along two 100 m spans of stressed ribbon at a sag of 2.00 per cent, carrying 35 kN/m, when 20 kN/m of live load is added to the left-hand span, with a rigid pier (dashed) and with a pier of 200,000 kN/m (solid). With a rigid pier the loaded span sags a further 195 mm and the other does not move. With a pier of 200,000 kN/m the pier top leans 25 mm towards the load, the loaded span sags 358 mm and the unloaded span rises 191 mm; the pier carries 4,953 kN of the 9,440 kN a rigid pier would. Structural form

The pier that carries only the difference

A stressed ribbon continued over a pier pulls on it from both sides, and under its own weight the two pulls cancel. Load one span and they do not: the pier is asked for the difference, nearly ten meganewtons for a crowd on one of two hundred-metre spans. Whether it gives it depends on its stiffness against a number the ribbon supplies itself, and whatever the pier does not carry, the ribbon turns into movement — a third of a metre of extra sag in the loaded span and a fifth of a metre of rise in the empty one.

The same riser, held three ways. The peak bending stress at each floor of a water-filled DN100 riser running the full height of the eight-storey building, under the same record, held three ways. Anchored against rotation at every floor it reaches 131 N/mm², at the lower floors where the drift is largest. Guided at every floor — held in line and free to turn — the same pipe never exceeds 3 N/mm². Guided everywhere but anchored at its base, it carries 77 N/mm² at the base and 21 N/mm² one floor up, and the guided values from there on. Dynamics

The pipe held at every floor

A riser runs the height of a building and is fixed at every floor, so each of its supports moves with a different floor. The floor spectrum prices the pipe's inertia, and for a pipe anchored at every floor the inertia is nearly irrelevant: the drift puts 131 N/mm² into a 100 mm riser at two thirds of a per cent, thirty times its inertia, and passes yield at 200 mm. Guide the same pipe instead of anchoring it and the drift almost vanishes — the pipe then feels only how much the drift changes from one storey to the next.

Weakest the day it is finished. The factor of safety against tipping of a 15,000 kN tower on a 10 m square base over soft clay (undrained strength 35 kPa, gaining 0.22 of the effective stress the tower puts into it, consolidating with a 90 per cent time of 7.1 years), through twelve years, for construction times of three months, one year and four years; its wind push grows as it rises. Built in three months, it bottoms out at 1.14 on the day it is finished; built in one year, it bottoms out at 1.33 on the day it is finished; built in four years, it bottoms out at 1.60 on the day it is finished. After that every curve climbs toward 1.93, the factor once the clay has consolidated. Had the finished weight arrived in an instant the factor would be 0.92; on ground that could not fail it would be 3.00. Equilibrium

The ground that arrives after the weight

A block's resistance to tipping on ground that can yield is a parabola in its weight, with its peak at half of what the ground can bear. On soft clay the ground's capacity is not fixed: it grows as the clay drains under the weight, and it grows years after the weight has arrived. A tower on such ground is at its weakest on the day it is finished — 1.33 against the 1.93 it will have once the clay has drained — and a silo filled in a week walks over the top of the parabola and down the far side, which is the other way a structure can be built.

Fully stressed, with a choice of diagonals. Two trusses sized so that every member is at the allowable stress under the full load, each member drawn as wide as its area, tension and compression in two colours. Above, an eight-panel Pratt truss as deep as a panel is long, with a counter-diagonal in each of its six interior panels, loaded by 10 at every bottom joint, found by resizing and reanalysing until nothing changes; below, the same truss without its counters. The counters in the two middle panels have shrunk to nothing (dotted) and the four nearer the supports have stayed, working in compression beside the diagonals in tension. The truss that kept them needs 1,200 units of steel against the Pratt's 1,220, and deflects 24.0 at mid-span against 26.0. Deflection

The truss whose forces follow its sections

In a determinate truss each member's force is fixed before its section is chosen, so sizing for strength and sizing for stiffness can be done in either order. Put a counter-diagonal in every panel and they cannot. The fully stressed design becomes an iteration that starves some counters to nothing and keeps others, lands on a different truss from every start, and — whichever it lands on — weighs the same and deflects the same. Then enlarge one group of members to stiffen it, and a vertical nobody touched is overloaded by 58 per cent.

Three members after a diagonal goes. The forces in three members of the counter-braced truss when the diagonal 9–2, carrying 242 kN, is removed instantaneously, with 2 per cent damping, over one and a half of the damaged truss's first periods (0.57 s); dashed, the static force each settles to. The counter-diagonal 1–10 goes from −112 kN to −354 kN and peaks at −491 kN, 1.57 times its change. The bottom chord 3–4 ends exactly where it started, 750 kN, and on the way peaks at 1,115 kN. The bottom chord 2–3 settles lower, at 556 kN, after a first swing the other way, to 905 kN. Structural form

The factor of two belongs to one mode

A member that fails suddenly hands its force to the structure around it all at once, and the convention is to double the static answer: a load applied suddenly to a spring overshoots to twice its static deflection. A truss is not one spring. Take a diagonal out of a counter-braced truss in an instant and some members swing to three times their change of force, one swings the wrong way first, and a bottom chord whose force does not change at all passes through half as much again as it carries — because every mode overshoots by two, at its own time, and a member is a sum of modes.

A soft layer over stiff ground, and a moment neither has. The bending moment down a 20 m pile of bending stiffness 120 MN·m² with a free head, pushed sideways by 150 kN (its characteristic length in ground at 5.00 MN/m³ being 1.89 m), in three grounds: all of it at 5.00 MN/m³; all of it at 0.50 MN/m³; and soft ground 2.0 characteristic lengths (3.8 m) thick over the other (dotted: the interface). The largest moments are 219 kN·m, 346 kN·m and 427 kN·m; the head deflections 20.4 mm, 81.4 mm and 61.6 mm. The layered ground gives a larger moment than either ground on its own: the pile bends as a pile in the soft layer would, and then meets ground that holds it. Internal forces

The layer a pile feels

A pile pushed sideways in uniform ground has one characteristic length, the fifth root of its stiffness over the ground's, and every answer is a multiple of it. Put a soft layer over stiff ground and that length stops existing. The head feels the top of the ground in proportion to the square of its own deflection, so an average weighted that way gets the head deflection within eight per cent. It gets the moment a quarter too low: with soft ground two characteristic lengths thick over stiff, the pile bends harder than it would in either ground alone, and the peak sits where the stiff ground takes hold.

Three grounds, three tipping pushes. The push against the lean it produces, in thousandths of a radian, for the 6 m square, 3,000 kN block on ground that bears 300 kPa at most, half of it mobilised at 7.5 mm of settlement, pushed 8 m up, its weight 5.0 m up, on the three grounds matched at their limit and at half of it; dashed, the rigid-plastic limit, 813 kN. Linear, capped: 776 kN at a lean of 13.2 thousandths; hyperbolic: 701 kN at a lean of 26.2 thousandths; S-shaped: 770 kN at a lean of 15.2 thousandths. The S-shaped ground behaves almost exactly like the capped one; the hyperbola, which never quite reaches its limit, tips 10 per cent sooner at twice the lean. Equilibrium

The ground that never quite gives way

On a bed of springs capped at the ground's bearing limit, a block pushed sideways tips at a definite push, below the limit the rigid-plastic parabola gives. Real ground is curved: it softens all the way to its limit and never quite reaches it. On such ground the block has no tipping push of its own. Its resistance creeps toward the limit, and the peak it does have is made by its own weight leaning with it — 14 per cent below the limit with the weight 5 m up, nearly at it with the weight at the base, where the lean simply runs away.

A deck holds the middle of the span. The twist along an 8 m open section on forks, free to warp, carrying 12 kN/m at 75 mm from its shear centre — 900 Nmm of torque per mm of span. With nothing fastened to it the beam twists 6.25° at mid-span; a deck resisting the top flange's rotation at 5.0 kNm per metre per radian holds it to 4.20°, and one four times as stiff to 2.10°. The deck works where the beam is weakest, in the middle; near the supports the beam's own torsional stiffness does most of the work whatever is fastened to it. Deflection

A deck is a spring, not a wall

An open-section beam loaded off its shear centre twists, and the usual reassurance is that the deck fastened to its top flange will stop it. The deck resists the flange's rotation with a stiffness per metre of span, and that stiffness has to be compared with the beam's own. On an 8 m beam a screwed deck of ordinary stiffness removes a third of the twist; on a 16 m beam the same deck removes three quarters, because the beam's torsional stiffness falls with the square of its span and the deck's does not.

The modes that tilt, and the ones that do not. Johansen's mechanisms for a 12 mm bolt with washers in single shear through 40 and 40 mm of timber of density 350 kg/m³, each with the rope term the fastener's axial resistance of 6.64 kN adds to it. Modes a and b, where the fastener only translates, gain nothing; the modes in which it tilts gain a quarter of its axial resistance, capped at a quarter of their own Johansen value. The joint's capacity rises from 5.02 kN (mode c) to 6.28 kN (mode c), 25 per cent. Connections

The pull that Johansen left out

Johansen's mechanisms treat a timber fastener as a beam in a bed of crushing wood, bent and pushed sideways and nothing else. A real fastener that tilts across the joint is also pulled along its own axis, and if a washer or a thread resists the pull, it clamps the two members together and adds to what the joint can carry. The addition is a quarter of the axial resistance, it goes only to the modes in which the fastener tilts, and it is capped by fastener type — nothing for a dowel, a quarter for a bolt, all of it for a screw — which is how a screw keeps gaining strength past the thickness at which Johansen's capacity stops.

Every one of these soils failed that slope. For a 10 m slope at 35° in soil of 19 kN/m³ with a pore pressure ratio of 0.25, over a firm stratum 5 m below its toe, which has slipped: the pairs of effective cohesion and friction angle that put its critical circle at a factor of safety of exactly one, by Bishop's method. At no friction the cohesion is 32.1 kPa; at 20° it is 12.4; at 40°, 2.0; and the line reaches no cohesion at 48.1°, where a skin of soil slides parallel to the face. Labelled, the depth of each pair's slip below the original ground: 13.6 m at 0°, 8.8 m at 5°, 7.4 m at 10°, 5.2 m at 20°, 3.6 m at 30°, 2.3 m at 40°. Equilibrium

A failed slope gives a line, not a soil

A slope that has slipped is the one full-scale strength test geotechnics ever gets, and the standard way to read it is to set its factor of safety to one and solve for the soil. One equation cannot give two strengths. What it gives is a line of cohesions and friction angles, every one of which fails the slope exactly, and the repair designed on one point of that line can be worth a factor of 1.07 or of 1.51. The slip itself says which point: each soil on the line fails along a different surface, and the depth of the scar is the second equation.

The interior panel is designed by the case that designs nothing else. The shear across the column-web panel at each kind of joint of a frame of two 8 m bays and two 4 m storeys with fixed bases, 457 mm beams and 254 mm columns with 8.6 mm webs, under five load cases, the worse direction of sway taken where there is one. Full gravity: roof corner 106, roof interior 0, floor exterior 143, floor interior 0 kN; One bay loaded: roof corner 115, roof interior 117, floor exterior 150, floor interior 154 kN; Sway: roof corner 25, roof interior 40, floor exterior 53, floor interior 89 kN; Gravity + sway: roof corner 131, roof interior 40, floor exterior 196, floor interior 89 kN; Pattern + sway: roof corner 141, roof interior 157, floor exterior 203, floor interior 242 kN. The floor interior panel is empty under full gravity and carries 89 kN under gravity with sway, the case that governs the members; under one bay loaded with sway it carries 242 kN — 2.7 times as much, more than any exterior panel's 203 kN, and 70 per cent of the web's shear resistance. Internal forces

The panel that gravity leaves empty

A corner joint's panel carries the difference between a beam's flange couple and half a column's shear, and full gravity load is what makes that large. An interior joint has a beam on each side, and under full gravity their two couples cancel: the panel between them carries nothing at all, in the load case that sizes every member around it. It fills under the two loads that are not symmetric. A pattern load hands it one beam's moment, and sway hands it two beams' moments turning the same way. Together they put more shear through it than through any exterior joint, in a combination that governs no member.

More props, heavier slabs — unless they go in after the weight. The heaviest load any slab carries during construction, as a multiple of its own weight, against the number of levels of props under the slab being cast. Every level a shore that carried the wet concrete and moves up with the formwork: 2.00, 2.25, 2.37, 2.44 w for one to four levels. One level of shores and the rest backprops, put in snug after the formwork is struck: 2.00, 1.50, 1.33, 1.25 w. The same number of props, differently timed: a shore enters the load path before the weight it carries and passes it down, and a backprop enters after and shares only what arrives later. Materials

Loaded twice over before it is a month old

A concrete floor in a building going up a storey a week carries, in its first weeks, the wet weight of the floors being cast above it, handed down through the props. By Grundy and Kabaila's arithmetic that is twice its own weight on a single level of shores, and more with more levels — 2.25 on two, 2.37 on three — because every prop that carried wet concrete passes its load down the stack. The same props put in after the formwork is struck carry nothing until something new arrives, and the peak falls to 1.5, 1.33, 1.25. The heaviest day of a floor's life is decided by when its props went in, not how many there are.

What the frame notices. An 8 m by 4 m portal whose columns stand on bases of every rotational stiffness, in units of the column's EI/L on a logarithmic scale: solid, the portal's sway under a load at the knee as a multiple of the fixed-based portal's; dashed, the columns' effective length factor in sway (fixed bases 1.13, pinned 2.26). Bolts sleeved 300 mm, 5.3 EI/L: 1.45 times the fixed portal's drift, an effective length factor of 1.30 and 75 per cent of its buckling load; as detailed, 9.1 EI/L: 1.28 times the fixed portal's drift, an effective length factor of 1.23 and 83 per cent of its buckling load; rigid by EN 1993-1-8, 30.0 EI/L: 1.09 times the fixed portal's drift, an effective length factor of 1.16 and 94 per cent of its buckling load. Connections

The fixed base the bolts decide

A column base drawn as fixed is a spring, and the component method says what it is made of: the grout squeezed under the flange, the plate bending under the bolt row, and the anchor bolts stretching over their free length. For a 500 mm plate on two M24 bolts the bolts are three fifths of its flexibility, so the base comes out at nine times the column's EI/L — under a third of what EN 1993-1-8 calls rigid — and no thickness of plate can lift it above fifteen. Leave the bolts free in sleeves for erection tolerance and it falls to five. The frame on it drifts 28 per cent more than a fixed-based one and buckles at 83 per cent of the load.

The roller's pressure, not the soil's. Horizontal pressure down the back of a wall, for backfill of 20 kN/m³ and φ′ = 30° behind a wall 3.0 m high, compacted by a roller of 60 kN per metre of its width. Dashed, the soil's own active pressure, Kₐ·γz (Kₐ = 0.33), and at-rest pressure, K₀·γz (K₀ = 0.50). Solid, Ingold's compaction envelope: rising as the passive limit γz/Kₐ to 27.6 kPa at 0.46 m, then constant at √(2pγ/π) = 27.6 kPa all the way down, since the active pressure would not reach it until 4.15 m. Its thrust is 76.6 kN per metre of wall against the active 30.0, and its moment about the base 106.3 kN·m against 30.0. Equilibrium

The pressure the roller leaves behind

A retaining wall is designed for the pressure of the soil it holds, a triangle growing with depth. The soil behind most walls was not tipped there. It was placed in layers and rolled, and each pass of the roller pushed the soil sideways against the wall harder than the soil's own weight ever could, and left most of that push locked in when it moved on. Behind a 3 m wall compacted by an ordinary vibrating roller the locked-in pressure is a constant 28 kPa from half a metre down, the thrust two and a half times the active triangle's and the moment at the base three and a half.

The rib yields long before it would buckle. The largest combined stress, axial plus bending, anywhere in a 60 m two-pinned parabolic rib at a 12 m rise (EI 250,000 kN·m²) with a 12,000 mm² section 1,000 mm deep, against a factor on 15 kN/m of dead load over the span and 6 kN/m of live load over the left half together. Dashed: first order; solid: second order; dotted: the 355 N/mm² yield stress. First order, the rib reaches yield at a factor of 1.73; second order, at 1.18. The same load pattern, spread uniformly, would bifurcate the rib at a factor of 2.97, the right-hand edge — which is the number the eigenvalue reports and a number the rib never reaches. Stability

The weight that bends a rib it cannot bend

A parabolic rib carries its own uniform dead load as pure thrust, with no bending in it at all. Put a live load on half the span and the rib bends in the shape of its own buckling mode from the first kilonewton, and the whole thrust, most of it from the dead load, multiplies that bending. The rib never reaches its buckling load. It yields well short of it, at a load its first-order check says it can carry.

One quantity, three names. The middle braced bay's share of the storey force (solid) and one end bay's (dashed), for a 48 by 12 m plate, 200 mm of concrete, spanning two 24 m bays between three braced bays of 100,000 kN/m each, under 40 kN/m, against a factor on the plate's stiffness as built, on a logarithmic scale. The share moves continuously from 61 per cent, a continuous plate on unyielding supports, to 33 per cent, the rigid plate. Left of 0.02 (shaded) ASCE 7 calls the plate flexible and assigns tributary shares, 50 per cent to the middle; the plate there actually gives it 59 per cent at the boundary. Right of 1.54 (shaded) EN 1998-1 calls it rigid and assigns stiffness shares, 33 per cent; at that boundary the plate gives 37. The plate as built, factor 1, gives 38 per cent to the middle and 31 to each end. Structural form

Rigid by one code and not by the other

A floor plate between shear walls shares its storey force out in proportions that move continuously with its stiffness, from a continuous beam's to a rigid body's. The codes put it in one of two boxes and use a different model in each. ASCE 7 and EN 1998-1 draw their boxes' edges a hundred times apart in plate stiffness, each at a point where its own licensed model already misstates the middle wall by about a tenth — and an ordinary 200 mm slab sits in the gap between them.

The same rib, fixed, bends at both ends as well as the crown. The bending moment that axial shortening leaves in a 60 m parabolic concrete rib at a 6 m rise (EI 420,000 kN·m², EA 20,400,000 kN) under 60 kN/m, sagging upward, from a frame solve of the rib. Dashed: two-hinged, sagging throughout, 29.4 kN·m at the crown. Solid: fixed at the springings, 57.9 kN·m sagging at the crown and 112.4 kN·m hogging at each springing. The funicular load itself leaves no moment in either rib; all of this is the 0.11 and 0.63 per cent of the thrust the two ribs lose by getting shorter. Deflection

The springings that make shortening worse

Fixing an arch at its springings is the stiffer, cheaper and usual way to build one in concrete, and it makes the arch six times as sensitive to its own shortening. The thrust it loses acts at the elastic centre, two thirds of the way up, so the moment lands at the springings as well as the crown, twice as large and the other way round — at the section the fixed arch is designed at, not away from it.

The perimeter the edge leaves, and where its middle is. A 400 × 400 mm column at the edge of a 260 mm slab (d = 225 mm) carrying 12 kN/m², on a 7.2 m end span. Heavy line: the control perimeter 2d out, cut by the slab's edge — 2,614 mm, against 4,427 for the same column inside the slab. Wide band beneath it: the reduced perimeter u1 of EN 1992-1-1, 2,214 mm, its legs cut back from the edge. Open circle: the perimeter's centroid, 363 mm in from the column's centre. Filled: the load's resultant, 631 mm in, set by the slab's end moment of 170 kN·m on a shear of 269 kN — 269 mm beyond it, into the slab. The general multiplier on the shear is 1.78; u1/u1 gives 1.18 and the shortcut 1.4. Internal forces

The perimeter whose middle is not the column's

At an edge column the slab's own edge cuts the control perimeter, and what is left has its centroid 363 mm inside the column's centre. The slab's end moment moves the shear's resultant inward too, by a distance that grows with the end span. What twists the perimeter is the gap between the two: nothing at a 5 m end span, enough by 7.2 m to put the check at 1.23 of its resistance where the 1.4 shortcut reads 0.97. And a bigger column makes it worse.

How stiff an abutment has to be to count as fixed. The shortening moments in a 60 m parabolic concrete rib at a 6 m rise (EI 420,000 kN·m²) under 60 kN/m as shares of the fixed rib's, against the rotational stiffness of each springing as a multiple of EI/L on a logarithmic scale: at the springings (solid, −112 kN·m when fixed) and the crown (dashed, 58 kN·m fixed, 29 two-hinged). The springing moment is half the fixed value at kθ = 11.3 EI/L and nine tenths at 102 EI/L; at EI/L itself it is 8 per cent. The crown moment never falls below the two-hinged rib's 51 per cent of the fixed value. Deflection

The abutment that spreads before it turns

A fixed arch is fixed only if its abutments hold still, and they have two ways not to. Turning releases the springing moment, but slowly: an abutment has to be a hundred times the rib's EI/L to hold nine tenths of it, and a footing on stiff clay under a slender concrete rib already is. Spreading does the opposite. The rib's own shortening is worth 13.6 mm of spread, so an abutment that gives 7 mm a side under the thrust doubles every secondary moment in the arch — and a footing on dense sand gives 8.

Lean a screw and its bending stops mattering. The peak load on an 8 mm fully threaded screw (yield moment 20 N·m, tensile capacity 20 kN) through two 100 mm softwood members of density 350 kg/m³, against the angle it is driven at to the joint: the joint, its two resistances added slip by slip (solid); the thread's alone, resolved along the joint with its friction (dashed); the bending and embedment's alone (dotted); and the square screw with the rope effect, 5.9 kN (thin). At 45 degrees the joint carries 13.4 kN, 2.3 times the square screw, of which the bending gives 1.8; at 30, 19.1. The bending is the larger share only steeper than 85.7 degrees, within 4.3 of square. Withdrawal is taken to peak at 1.5 mm of axial movement and soften after it; bending follows Foschi's curve from EN 1995-1-1's slip modulus — shapes, not measurements. Connections

The screw that is pulled instead of bent

A screw square to a timber joint resists slip by bending, and its thread is engaged only when it has tilted far enough to be pulled. Lean the same screw to 45 degrees and the slip pulls it from the first millimetre. An 8 mm screw through two 100 mm members goes from 5.9 kN to 13.4, reached after 2.2 mm of slip instead of more than twelve, and the bending that Johansen's model is about becomes an eighth of the joint. The price is a joint that holds one way better than the other.

The floor under the reduction rises with the correlation. The least factor a column carrying ever more floors may take, against the correlation between floors, for an office imposed load with a coefficient of variation of 0.6, its characteristic value the 95th percentile, loads normal: (1 + zv√ρ)/(1 + zv). With independent floors it is 0.503, the floor the independence argument found; at a correlation of 0.1 it is 0.660, at 0.3 0.775, at 0.5 0.855. EN 1991-1-1's storey rule falls to ψ₀ = 0.70 (dashed), and the two cross at a correlation of 0.157: floors that move together any more than that make the rule's tall-building reduction larger than the averaging can pay for. Equilibrium

The floors that fill up together

A column may be designed for less than the sum of its floors' imposed loads because the floors do not reach their worst day together — an argument that assumes each floor's load is independent of every other's. Let any two floors be correlated, and the reduction the averaging can pay for shrinks, and stops shrinking at a higher floor. At a correlation of 0.16 that floor reaches the 0.7 the storey rule falls to. One tenant on five floors halves what twenty floors can average away.

The buckling mode moves up to where the spine is not. The building's first buckling mode, each floor's sideways movement as a fraction of the roof's, up the height of a 20-storey building of a bending spine and a racking frame (αH 1.0), its gravity scaled to an elastic critical factor of 5.0, under an equal lateral load at every floor: the spine to the roof, and stopping at storeys 15 and 10. With the spine to the roof the mode is the bending tower's, growing all the way up. With the spine stopping, at storey 15 its top moves less than a thousandth as far as the roof, and at storey 10 its top moves less than a thousandth as far as the roof: the building buckles in the first storey of frame above the spine, every floor above that storey moving with it as one, and the spine takes no part. Stability

The storey above the core decides

A building whose bending core runs to the roof shares one sway mode between its core and its frame, and the storey-by-storey stability check reads it wrongly twice. Stop the core five storeys short and the check becomes exact: the first storey of bare frame above the core reads the building's own critical factor to three figures, because the whole building buckles there and nowhere else. The check stays wrong below the core, and it goes wrong again when the frame above is more than about twice as stiff.

The interior web pulls the shear centre toward itself. The shear centre of a two-cell box 600 mm wide and 300 mm deep on its centrelines, 10 mm walls, its interior web 200 mm from the left, its distance from the left against the interior web's thickness as a multiple of the other walls', on a logarithmic scale. The single box's middle is 300 mm (dashed) and the web is at 200 (dotted). A web a hundredth as thick as the walls moves it 0.6 per cent of the way; a tenth, 5; as thick as the walls, 27; half way at 5.4 times; a hundred times, 92. Sections and stress

The web that moves the centre and not the twist

A thin plate closing a channel into a box changes its torsion at once and its shear centre hardly at all. An interior web dividing a box into two cells does the reverse. Off the middle of a 600 mm box, a web as thick as the walls takes 38 per cent of the vertical shear — more than either outer web — and pulls the shear centre 27 mm toward itself, while the torsion constant changes by less than one per cent. The two walls are the same kind of wall; what differs is which flow they are part of.