One essay so far on this idea, and more questions about it than one essay answers.
  1. Two cantilevers, or one wall, and the beams decide which. The deflected shape of a coupled pair of 6 m walls, drawn against the two limits it lies between. Release the coupling beams entirely and the pair is two independent cantilevers, deflecting 111 mm. Make them rigid and it is one composite wall of the full width, deflecting 16 mm — 6.8 times stiffer, because the lever arm between the wall centroids is 8.40 m and everything inside either wall is smaller than that. Real beams of 600 × 350 mm over a 2.4 m opening land at 23 mm and carry 63% of the base overturning as an axial couple rather than as wall bending. The degree of coupling never reaches one, because a beam of finite depth cannot suppress the walls' curvature entirely.

    Two walls that agreed to be one

    A pair of shear walls with a row of doors between them is the commonest lateral system there is, and it has two readings that differ by a factor of seven. What decides which one applies is a beam 600 mm deep over a 2.4 m opening — and most of the overturning ends up as an axial couple that no bending diagram contains.