Series

Tied arch — the series

One essay so far on this idea, and more questions about it than one essay answers.
  1. The tie is a redundancy, so its stiffness decides the thrust. Thrust and rib bending for a 60 m tied arch of 0.15 rise ratio, against the stiffness of its tie. Cut the tie and the structure is a curved simply supported beam, so the tie force is the one redundant and the force method gives it: with a rigid tie the answer is 2227 kN, within 1.0 per cent of the funicular wL²/8f, and the shortfall is the arch's own axial shortening. A real tie stretches 68 mm and returns 2166 kN — 2.7 per cent of the flexibility is the tie — and whatever thrust the arch does not get, it carries as bending: 760 kNm at 30 m. A tenth of the tie stiffness is not a tenth of the problem; it is a different structure.

    The thrust that never reaches the ground

    Every arch on this site has ended at the same sentence — the foundation is where an arch is really decided. A tie changes the sentence without changing the arithmetic: the horizontal force is still there, still the same size, and it now closes on itself through a bar at deck level.

    part 1 · structures

All series