Series
Tapered member — the series
2 essays on one idea, from the one that introduces it to the one that assumes the rest.
-
The section that changes along the span
A prismatic beam is checked where the moment is largest, and everyone knows where that is. A tapered one is not, because the capacity is moving too — and for a cantilever with a load at its tip the governing station is exactly where the depth has doubled, with no length, no load and no material in the answer.
-
The section that governs is inside the haunch
A tapered cantilever has its worst section somewhere along it because the moment grows linearly and the modulus quadratically. A haunched rafter has the same competition with a step in it, and the step is where the check lands — at neither end of the member, at a station no formula names.