Series

Saint-Venant's principle — the series

One essay so far on this idea, and more questions about it than one essay answers.
  1. Three ways to apply the same force, and one depth to forget the difference. Three end loads on a member 400 mm deep, all with the same resultant and the same moment: a point load, the same force spread over a fifth of the depth, and the same force split in two. What is plotted is the difference between each of them and the beam-theory answer — the self-equilibrating remainder — as a fraction of the mean stress. The point load starts at 20 times it and is under a tenth of it by 0.77 depths; all three are under one per cent by about 1.18. That distance is the licence every figure in this collection is drawn under, and the exact strip eigenvalue agrees with it: 2.106 + 1.125i, whose real part puts one per cent at 1.09 depths and whose imaginary part means the remainder changes sign on the way out, which no statement of the principle mentions.

    How far a wrong load reaches

    Every figure in this collection applies a load as a point, a line or a uniform pressure, and no real load is any of those. The licence is Saint-Venant's, it is usually quoted as a principle, and it is really a statement about a wavelength.

    part 1 · internal-forces

All series