Pounding — the series
-
The gap between two buildings
Two towers side by side in an earthquake need a gap. The obvious answer is the sum of what each can move, and it is wrong — because the two peaks do not happen at the same instant. What decides the answer is the ratio of the two periods, and buildings that sway alike need almost no gap at all.
-
The floor that arrives at a column
The gap between two buildings is computed from their roof displacements, which is where each of them moves most. It is not where they touch, and it is not what is there when they do — a slab edge meeting a column part way up its height is a different event from two slabs meeting, and it is the one that appears in the photographs.
-
The force that belongs to the model
When two buildings meet, momentum decides what each of them feels, and no contact law can change it. What the contact law decides is the force, and the force it reports is the contact stiffness somebody assumed, raised to a power. Four laws and a hundredfold change of stiffness move the buildings by a few per cent and the force by a factor of eight.
-
The damper that ends up as a joint
A damper across the gap between two buildings acts on exactly the motion the gap is sized for, and it can be sized for two different things. The size that takes the most energy out of the pair still lets the buildings collide. The size that keeps them apart has nearly stopped moving: it has joined them into one building, and the stiffer of the two pays for it in drift.
-
The force a filler can promise
A crushable filler in the gap between two buildings replaces a contact stiffness nobody knows with a crush strength somebody chose, and the force of a collision becomes that strength — for as long as the filler has thickness left to crush. Energy decides how much thickness that has to be, and in a gap sized for buildings that were never meant to meet it is not much.
-
The filler that cannot be gentle twice
A crushable filler in the gap between two buildings caps a collision at its crush force, but a filler soft enough to make the everyday contacts gentle runs out on the hardest one. Grade it — soft at the face, strong behind — and the soft layer takes the small contacts while the strong layer stops the large. The energy says otherwise. Every kilojoule the soft layer does not absorb, the strong layer must, in less depth: in a 40 mm filler, an outer half at 1.5 MPa needs an inner half at 56 MN, far above the 35 MN of the bare concrete it was meant to improve on.
-
The filler that knows how fast it is hit
A filler graded through its depth meets the small collisions softly and the hard one with a strong layer that has to be very strong, because every kilojoule the soft layer misses must be absorbed in less depth. A filler whose strength rises with the speed it is crushed at ranks collisions by speed instead, with no layers at all, and treats the middling collisions better than grading does. But it meets every collision hardest at its first instant, when the crushing speed is greatest, and a force that falls as the collision proceeds needs a higher peak to absorb the same energy in the same depth. A purely viscous filler that stops the hardest collision in 24 mm hits it with exactly twice the force of a uniform one.
-
The filler that is used up before the worst
A crushable filler between two buildings is sized for the hardest collision it might meet, meeting it new. An earthquake does not oblige: the hardest contact arrives after a dozen middling ones, and each has taken some of the depth. Through a record of six cycles, a filler half of whose strength follows its crushing speed is dense before the worst contact arrives, and a uniform one has five millimetres left. A graded filler still has twelve. Yet the graded filler meets the worst contact at 56 MN and the spent rate-sensitive one at 39. Keeping depth is not the same as being gentle, and the order of the contacts barely matters.