Series

Patch loading — the series

2 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The bearing is one length and the web is loaded over another. A load applied over a stiff bearing of 100 mm on the flange of a girder with a 1200 × 8 mm web. The flange bends under it and the yield lines that form spread the load along the web over 559 mm — 5.6 times the bearing, and 82% of the yield resistance is that spread rather than the bearing. The effective length is not a decision anybody made: it is what the flange's own bending stiffness against the web's own strength works out to.

    The load that chooses its own length

    Every other load in this collection arrives over a length somebody decided. A wheel on a crane girder does not — the flange bends under it and spreads it along the web, and how far it spreads is an output of the flange's own stiffness against the web's own strength. The effective length is 5.6 times the bearing that produced it.

    part 1 · stability
  2. The stub column a bearing stiffener makes, in plan. A plan through the girder at the bearing. The 8 mm web runs across; the pair of 100 × 12 stiffeners stands off it; and the shaded strip of web either side — 15ε t_w, or 98 mm each way — is the width that buckles with the stiffeners rather than independently of them. Together they are an area of 3962 mm² with a second moment of 9.01·10⁶ mm⁴ about the web's centreline, a radius of gyration of 48 mm over a buckling length of 900 mm — 0.75 of the depth, because the flanges hold the ends. That is a slenderness of 0.25, at which the column curve returns 0.98: the stub column reaches 98 per cent of its squash load, and the section's own strength is very nearly the whole answer.

    A column nine hundred millimetres long

    The patch-load check asks how much of a web a flange can spread a wheel over, and answers in a plate-buckling reduction that throws seven tenths of it away. A pair of stiffeners does not improve that answer. It replaces the question with a different one, from a different family, with a different failure in it.

    part 2 · stability