Generator

Where a beam's load comes from

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
Where a beam's load comes from. A 8 × 6 m panel carrying 5 kN/m², divided at 45° from the corners. The long beams take a trapezoid of 15.0 m² each and the short beams a triangle of 9.0 m²; the four areas sum to 48.0 m², which is the panel, so no load has been invented or lost. The line loads quoted are the uniform equivalents; the real distributions peak at 15.00 kN/m at midspan.

Where a beam's load comes from. A 8 × 6 m panel carrying 5 kN/m², divided at 45° from the corners. The long beams take a trapezoid of 15.0 m² each and the short beams a triangle of 9.0 m²; the four areas sum to 48.0 m², which is the panel, so no load has been invented or lost. The line loads quoted are the uniform equivalents; the real distributions peak at 15.00 kN/m at midspan.

8 essays call tributary-load. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

Where a beam's load comes from. A 8 × 6 m panel carrying 5 kN/m², divided at 45° from the corners. The long beams take a trapezoid of 15.0 m² each and the short beams a triangle of 9.0 m²; the four areas sum to 48.0 m², which is the panel, so no load has been invented or lost. The line loads quoted are the uniform equivalents; the real distributions peak at 15.00 kN/m at midspan. Equilibrium

The load a beam is given is a decision

Every beam calculation so far has started with a load per metre, handed over as though it were a property of the beam. It is not. It is the answer to a prior question nobody draws, and two defensible answers to it differ by sixty per cent on the same floor.

A two-way slab is a one-way slab as soon as it is not square. The share of the load carried by the strips spanning the short way, against the ratio of the sides. The two families of strips cross at the centre and must deflect equally there, and a strip's deflection goes as the fourth power of its span — so at a ratio of 1.33 the short strips already take 76% and at 2 they take 94%. The panel drawn here is 6 × 8 m, a ratio of 1.33, and its short strips take 76.0%. Two-way action is worth having at a ratio of one and worth almost nothing by two. Structural form

The slab that spans both ways

A panel supported on four sides sends its load in two directions at once, and the share is decided by a fourth power — so a panel a third longer than it is wide has already stopped being a two-way slab in any useful sense. What it does at collapse is a different calculation with a different answer.

Two beams tied together, and the deeper one takes 89% of the load. Two simply supported beams of 6 m, one twice as deep as the other, tied together at midspan so that they have to move as one. A load of 100 kN stands on the tie. Point stiffness is 48EI/L³, so the deeper beam is 8 times as stiff — depth cubed, nothing else — and the load divides in that ratio: 11.1 kN into the shallow beam and 88.9 kN into the deep one, 11% against 89%. Both midspan points move 5.00 mm, which is the whole of the argument: the geometry of the load never entered it. The deflection is drawn 78 times full size — the real sag is 5.00 mm on a 6 m span, about 1 in 1200. Internal forces

The stiffest path takes the load

When two members share a force the split can be argued about. When they share a displacement it cannot — stiffness settles it, and nothing about the load or the plan drawing gets a vote. The consequence is that stiffening a lightly loaded member raises its stress, and the way to unload something is to soften it.

Whether the floor shares the load out by stiffness or by area. The share of a uniform storey force taken by each of three equally stiff walls, against the stiffness of the floor plate that spans between them. A plate far stiffer than the walls translates almost rigidly, every wall deflects the same and the share is the ratio of stiffnesses — 60% to the middle wall here, the same as everyone else. A plate far softer than the walls behaves as a continuous beam over them and the middle wall takes 33%. Neither end is the tributary-area answer of 50%, which assumes a plate that is both soft and discontinuous over the wall, and which nothing here ever reaches. Structural form

The floor is a beam lying down

A floor plate spans horizontally between the walls that resist a lateral load, carries a distributed inertia load, and has chords, a web and a span-to-depth ratio like any other beam. Its stiffness decides whether the walls share the load by their stiffness or by the area of floor nearest them — and the familiar tributary answer turns out to be neither limit.

The snow that left the roof is standing against the wall. A roof in section with a 1.0 m obstruction at its downwind end, drawn with the vertical scale exaggerated 4 times because a metre of snow on twenty metres of roof is thinner than the line it would be drawn with. The balanced layer is 0.48 kN/m² everywhere; the wedge against the wall holds the snow that 30% of the 20 m upwind gave up, so its area is fixed by conservation of mass rather than chosen. That makes it 0.85 m deep and 3.4 m long, with a peak load of 2.60 kN/m² — 5.4 times the balanced value, and still only 27% of the snow on the roof. An intensity several times the design load, made of a quantity nobody would notice had moved. Equilibrium

The load that arrives where the wind stops

Snow is the one load a structure is given rather than subjected to. What falls is spread evenly over a whole region; what a member carries is whatever the wind left above it, and the wind piles it against whatever gets in the way. The heaviest patch on a roof is usually a quarter of the snow on it.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached. Equilibrium

The load that is really a lean

No frame is ever plumb. The columns are out of upright by something like a three-hundredth, and every tonne of gravity load standing on that lean has a horizontal component. The force that represents it is not a safety allowance — it is an exact statics substitution for a geometry nobody drew.

Independence, and the floor it never goes below. The reduction factor a column is allowed, two ways. The Eurocode storey rule falls to 0.70 and stops. The independence argument — n bays each with a mean and a standard deviation, summed — gives (1 + zv/√n)/(1 + zv), which falls faster and stops at 0.503: a floor with no n in it at all, decided only by how variable the load is and how far out the fractile is drawn. The mean is never reduced away, because every bay really does carry its mean. At ten storeys the two differ by 10.0 points. Equilibrium

The load that is never all there at once

A column at the bottom of twenty storeys is designed for the imposed load of twenty floors added up, and twenty floors do not reach their own worst day together. The reduction that follows is not a discount on the safety margin. It is the central limit theorem, and it has a floor it never goes below.

The column under the first interior support is given a quarter more. Two equal spans of 8.0 m carrying 5.0 kN/m, continuous over three supports. The tributary rule gives each interior support one span's worth of load, 40.0 kN, and each end support half of that. The continuous beam gives 15.0 kN, 50.0 kN, 15.0 kN — ratios of 0.75, 1.25, 0.75 to what the areas say. The reactions still add to the whole load, because they must; what has moved is which support gets it. The end supports are relieved because the span next to them hogs over the first interior support, lifting their end of it. Equilibrium

The column given more than its rectangle

The tributary rule draws a rectangle round each column and hands it whatever stands inside. A floor is continuous over its columns, and a continuous beam does not give each support the load above it — the first interior one takes a quarter more and the end ones a quarter less. On a grid the two directions multiply, and two columns on the same floor differ by a factor of nearly three.

The library, page 6 of 7 — where tributary-load sits