Generator

A pile has no length until the ground gives it one — the pile lateral generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
A pile has no length until the ground gives it one. Deflection, bending moment and soil reaction down a 0.6 m pile carrying 150 kN at a free head, in ground whose modulus grows by 0.005 N/mm³ per millimetre of depth. The one length in the problem is T, the fifth root of EI over n_h, which is 1.89 m here; the head moves 20.5 mm, the worst moment of 219 kNm is at 2.50 m — 1.32 T — and below about four T nothing happens at all. The classical coefficients come out of the finite differences rather than a table: 2.430 against Matlock and Reese's 2.435, and 0.772 against their 0.772.

A pile has no length until the ground gives it one. Deflection, bending moment and soil reaction down a 0.6 m pile carrying 150 kN at a free head, in ground whose modulus grows by 0.005 N/mm³ per millimetre of depth. The one length in the problem is T, the fifth root of EI over n_h, which is 1.89 m here; the head moves 20.5 mm, the worst moment of 219 kNm is at 2.50 m — 1.32 T — and below about four T nothing happens at all. The classical coefficients come out of the finite differences rather than a table: 2.430 against Matlock and Reese's 2.435, and 0.772 against their 0.772.

4 essays call pile-lateral. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

A pile has no length until the ground gives it one. Deflection, bending moment and soil reaction down a 0.6 m pile carrying 150 kN at a free head, in ground whose modulus grows by 0.005 N/mm³ per millimetre of depth. The one length in the problem is T, the fifth root of EI over n_h, which is 1.89 m here; the head moves 20.5 mm, the worst moment of 219 kNm is at 2.50 m — 1.32 T — and below about four T nothing happens at all. The classical coefficients come out of the finite differences rather than a table: 2.430 against Matlock and Reese's 2.435, and 0.772 against their 0.772. Internal forces

A pile has no length until the ground gives it one

Almost every other structural member is handed a length by the drawing. A pile goes into the ground until it stops, and what decides how much of it is working is a fifth root of the ratio between its own stiffness and the soil's.

Most of a long pile is doing nothing. Head deflection against embedded length, both measured in the pile's own characteristic length T = 14.67 m. A pile shorter than about two T is a lever with nothing holding its foot and deflects several times as much; past four T the curve is flat to within a per cent, because the ground below that depth is never asked for anything. A lateral check is a check on the top four T of a pile, however deep it goes for its axial load — and adding length to fix a lateral deflection is the one remedy that does not work. Internal forces

The pile that is too short to bend

A laterally loaded pile is long or short in its own characteristic length, and the two are different structures. The slender pile bends and the ground below four characteristic lengths never hears about it; the monopile is two lengths deep, rotates about a point, and every tabulated coefficient written for the first case is wrong for the second.

A soft layer over stiff ground, and a moment neither has. The bending moment down a 20 m pile of bending stiffness 120 MN·m² with a free head, pushed sideways by 150 kN (its characteristic length in ground at 5.00 MN/m³ being 1.89 m), in three grounds: all of it at 5.00 MN/m³; all of it at 0.50 MN/m³; and soft ground 2.0 characteristic lengths (3.8 m) thick over the other (dotted: the interface). The largest moments are 219 kN·m, 346 kN·m and 427 kN·m; the head deflections 20.4 mm, 81.4 mm and 61.6 mm. The layered ground gives a larger moment than either ground on its own: the pile bends as a pile in the soft layer would, and then meets ground that holds it. Internal forces

The layer a pile feels

A pile pushed sideways in uniform ground has one characteristic length, the fifth root of its stiffness over the ground's, and every answer is a multiple of it. Put a soft layer over stiff ground and that length stops existing. The head feels the top of the ground in proportion to the square of its own deflection, so an average weighted that way gets the head deflection within eight per cent. It gets the moment a quarter too low: with soft ground two characteristic lengths thick over stiff, the pile bends harder than it would in either ground alone, and the peak sits where the stiff ground takes hold.

Where the shelter is decides whether the leading row works harder. The share of the cap's shear the leading row and the last row of three rows carry, as a multiple of the average pile's, against the thickness of soft ground over stiffer, in characteristic lengths, with the row factors applied at every depth (solid) or in the soft layer only (dashed). With the factors at every depth the leading row carries 1.24 and the last 0.83 at 2.0 lengths; in the soft layer only, 1.07 and 0.96. In uniform ground the usual reading gives 1.35 and 0.75. Internal forces

The shelter that stops at the interface

Piles in a group shelter one another, and practice counts the shelter as a factor on each row's soil, calibrated on groups in uniform ground. Put the same group in soft ground over stiff and the calibration has to be read one of two ways — the shelter at every depth, or only where the ground is soft — and the two readings disagree about which row works hardest. The first gives the leading pile 17 per cent more moment at the cap; the second gives the last pile 24 per cent more in the ground.

The library, page 4 of 7 — where pile-lateral sits