The joint-length generator
The end bolts do the work and the middle ones very nearly nothing. A lap of 8 bolts at 70 mm pitch transferring 800 kN between two plates, with the force each bolt actually carries drawn above it and the flat line a division by the bolt count would have given drawn behind. The end bolts carry 1.09 of their nominal share and the middle ones 0.94. The reason is not in the bolts: at the leading end the first plate is carrying everything and the second nothing, so the two strain at different rates and the slip between them is largest there. In the middle they strain alike, there is almost no slip, and a bolt with no slip across it transfers almost no force. The mean over the worst is 0.918, and the end bolt has to slip 1.36 mm before the rest catch up.
2 essays call
joint-length. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever
member of the family the generator happens to default to rather than the one its essay
argues about.
Where it is called
Changing this generator changes every one of these figures.
The force that arrives along a length
A bolt takes its force at a hole and a weld along a line. A reinforcing bar has no such place — it is a smooth cylinder in a hole of its own shape, and the only thing stopping it sliding out is a stress smeared over its surface. So the force in it is not a number, it is a function of position.
ConnectionsThe bolts that do not share
Every bolted connection in this collection has divided a force by a number of bolts. That is right for a short joint and wrong for a long one, and the reason has nothing to do with the bolts — it is that the plates they join are elastic, and stretch by different amounts at different points along the lap.