A brace is a stiffness requirement, not a strength one
A brace is a stiffness requirement, not a strength one. Critical load against brace stiffness for a pinned column braced at mid-height. The curve climbs from the unbraced Euler load of 9.87EI/L² and flattens at 39.48EI/L², which is the Euler load of the braced segment — past that the column buckles in a shape the brace does not obstruct, and further stiffness buys nothing. The knee is at about 159EI/L³.
15 essays call
brace-stiffness. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever
member of the family the generator happens to default to rather than the one its essay
argues about.
Where it is called
Changing this generator changes every one of these figures.
The brace that need not be strong
A brace holding a column at mid-height carries almost no force. What it has to be is stiff — and the stiffness required is exact, large, and reached at a knee past which more buys nothing at all.
Guessing the shape, and getting the load anyway
A column's buckling load can be had from a shape that is wrong everywhere, because the energy criterion is stationary at the true mode. The error in the load is the square of the error in the shape, and it is always high.
The brace on the wrong flange
A brace on a column has one property that matters, and it is stiffness. A brace on a beam has two, and the second decides whether the first is worth anything: put the identical restraint on the tension flange and it does not reach the answer at any stiffness whatever.
Held everywhere, and it forgets its length
A brace at a point divides a member's buckling length. A restraint spread along the whole member does something else — the member chooses its own number of half-waves, and past a few of them the critical load stops depending on the length at all.
The load that moves with the twist
A beam about to buckle sideways is beginning to rotate, and everything attached to it rotates with it. A load hung from the top flange swings out over the side and drives the rotation on; the same load hung underneath swings back and stops it. Two identical beams, two different capacities, and the only difference is a height.
The rib that is a boundary condition
A rib on a plate is not a member carrying load. It is a line the buckle is not allowed to cross — and it becomes one at a threshold. Below the required rigidity it rides on the buckle and buys a fraction; at the threshold it stays straight and the plate buckles between stiffeners; above it, nothing further happens at all.
The shape of the diagram, and not its peak
A beam's lateral-torsional capacity is quoted against uniform moment, which is the one case a beam carrying a load never has. Change the shape of the moment diagram without changing its peak and the buckling moment moves by a factor of nearly three.
Twice the moment, four times the brace
A lateral brace has to be on the right flange and its demand is very nearly linear in the load. A torsional brace has no flange to be wrong about, and its demand is exactly quadratic — so the restraint that is indifferent to where it is attached is the one that gets expensive fastest.
The stiffness a row of braces shares out
One torsional brace at midspan has a ceiling, the moment at which the beam gives up twisting it and buckles in two half-waves instead. A row of braces raises the ceiling with every brace added, and the stiffness each must have to reach its ceiling rises with the count — seventy-four times as much for eight braces as for one. That is the right answer to the wrong question. Asked for the moment the beam has to carry rather than for its ceiling, a row of braces needs very nearly the same total stiffness however many it is divided between, so each brace gets softer as the count goes up. The count has one job, which is to put the ceiling above the moment; the stiffness has the other.
Three braces where the moment is
A row of torsional braces is spaced equally because that is how it is drawn, and under a uniform moment equal spacing is very nearly the best there is. Under a moment that peaks at midspan it is not. Moving the outer two of three braces toward the middle cuts the total stiffness a 24 m girder needs by a quarter under a uniform load and a third under a point load, and the bays it leaves at the ends cost nothing, because they carry so little of the moment.
The braces that stay where the framing puts them
Three cross-frames on a girder usually go where the floor beams or the bridge's bays put them, and cannot be moved toward the moment. They can still be made unequal. Giving the middle one three-fifths of the row's stiffness saves a sixth of the total under a uniform load and more than a quarter under a point load — most of what moving them would save. Moved and graded together, they save no more than moved alone, because both are ways of making every brace twist by the same amount.
The braces that have to hold each other
One brace at mid-height must have a stiffness of twice the column's load over the length it halves. Spread the same column over four braces and each one must be stiffer, not softer: 3.62 times the load over its segment, rising towards four with every brace added, because the shape the braces have to stop is a zigzag in which every brace point is pushed by both its neighbours. Braces that tie the column to itself instead of to the ground need one, however many there are. A row with surplus stiffness can carry one brace at two thirds of the ideal, but not one that is missing, and the force each brace has to resist grows with the count.
The braces that pull only one way
A brace made of a single tie, or a cross-frame whose diagonals can only pull, resists a girder twisting one way and not the other. A buckling girder has no preference between the two directions, so it takes the one its braces leave free. Three such braces all facing the same way leave a 24 m girder exactly as weak as if they were not there. Facing alternately, they reach 3,087 kN·m at the stiffness that takes two-way braces to 5,627, and no stiffness takes them past 4,063. Opposing the outer pair does not help; one one-way brace anywhere in the row is enough to cap it. Every brace has to resist both ways, and made of ties that costs twice the steel.
The braces with slack in their bolts
A cross-frame bolted into clearance holes resists nothing until the girder it braces has twisted far enough to take up the clearance, and then resists fully. It is a two-way brace that starts late. The girder, erected a little crooked, twists freely into its braces while the load is still small, and from then on the braces hold a girder that is more crooked than the one they were fitted to. The slack acts as an imperfection, and a costly one: each milliradian of it adds more to the middle brace's force than a milliradian of extra crookedness would, and no stiffness takes it back out. On a 24 m plate girder braced at twice the stiffness it needs, three milliradians of slack — a pair of ordinary clearances over its depth — raise the middle brace's force by 70 per cent.
The floor the columns lean on
A storey of pin-ended columns, every one a little out of plumb, leans on its floor, and the floor leans on a core. Count the floor as rigid and the core needs the sum of the columns' demands. A floor that shears in its own plane is a brace in series with the core, and the far columns lean on it before their push arrives. With a floor a hundred times stiffer per bay than a column's own sway softening, the storey's buckling factor falls from 4.0 to 1.5 and the core is asked for twice as much.