The collection

Every essay — page 28

Essays 649 to 672 of 728, in the same order.
The single side's strongest direction is not the double side's. The resultant a millimetre of throat can carry in S355 against the direction of the load: a double-sided butt throat, a fillet throat, and a 20 mm plate's single-sided throat at penetrations of 0.5 and 0.7, counted plastically. The double-sided butt is strongest at 22.7°, 478 N/mm². The single side at 0.5 rises from 183 straight across to 314 straight along and is strongest along the weld; at 0.7 it rises from 291 to 357 at 40° and falls to 314, and from 38° to 88° it carries more than the fillet. Connections

The root that has to stretch for it

A partial-penetration weld made from one side carries its pull off the plates' line, and counted elastically it keeps a quarter of a double-sided weld at half penetration. Let the throat yield and it keeps 0.41 — but the same 0.41 at every direction up to the one where the double-sided weld is strongest, so that weld's peak advantage is never won back. What the yielding does instead is move the single side's own strongest direction out to 40° or beyond, where a deep single-sided throat outcarries a fillet. Every per cent of it is paid for with strain at the root, which is the tip of an unfused land.

7 figures · Weld strength
What it costs depends on the load it must still carry. The steel in an eight-panel Pratt truss with a counter-diagonal in each interior panel, loaded by 10 at every bottom joint, sized to survive the loss of any one interior diagonal, against the share of the full load it must carry with the diagonal gone; the intact fully stressed design's 1,200 and the Pratt truss's 1,220 as level lines. At a third of the full load the robust truss needs 1,221, at a half 1,252, at two thirds 1,304, at the full load 1,555, and at four thirds — two thirds with the loss counted as sudden, doubled — 2,074. From about a half the interior diagonals grow in proportion to the load, each sized by its partner's loss; past the full load the chords grow too, because the damaged truss is then carrying more than the intact one was sized for. Deflection

The truss sized to lose a diagonal

A Pratt truss with a counter-diagonal in every interior panel, sized fully stressed, starves its middle counters to nothing and saves a little steel over the plain Pratt. Ask it to survive the loss of any one diagonal at the accidental two thirds of its load and the family of equal designs collapses to one: every counter comes back, sized by its partner's loss, and the truss needs 1,304 units of steel against 1,200 — 9 per cent for an alternative path the Pratt cannot have at any price. A lost chord can be survived too, by the panel's diagonals turned into a chord, for twice the steel. Four members in the end triangles cannot be survived at all.

6 figures · Truss deflection
The same damper behind a lever is best at a larger motion. The damping of one storey with 2% of its own damping and a brace as stiff as the storey, with an α = 0.3 damper sized to its brace's best at the design amplitude with no amplifier, against the storey's amplitude, with the same damper behind stroke amplifiers of ratio 1, 2 and 3. A ratio f makes the damper act on the storey as one f to the power 1 + α larger — 2.46 and 4.17 times — so it locks more, and its band moves up by about f to the power (1 + α)/(1 − α): its best is near 3.8 and 7.5 times the design amplitude. At a hundredth of the design amplitude all three give 1.4%; at the design amplitude 22.7%, 6.4% and 2.3%. Dynamics

The lever that moves the damper and not the band

A damper whose force goes as a low power of its speed is sized for the earthquake and locks in the wind. A toggle or scissor linkage multiplies its stroke, and it seemed it might move the band of amplitudes the damper serves down towards the wind. It cannot. Behind a lever of ratio f the same damper acts on the storey as one f to the power 1 + α larger, so its band moves up, not down; re-sized to the design amplitude, it gives the storey exactly the curve it had without the lever, and what has changed is the damper — a quarter of the size, a third of the force, three times the stroke. What would widen the band is a ratio that grows with the motion, and a toggle has one — until its links lie straight and it locks.

6 figures · Damping
The mechanism outcarries the frame that is nearly one. The load on the joint of two bars of 200 MN axial stiffness across 8.0 m against how far it moves down, followed to large displacement: the flat pair with its bars tensioned to 0, 50 and 200 kN with nothing applied, and the same bars raised 3 degrees with no tension, a rise of 210 mm. The raised frame is stiffer at first and snaps through at 11.1 kN, 89 mm down. The flat pair at 200 kN starts at 100 N/mm, carries 11.1 kN at 89 mm and 50 kN at 210 mm, and goes on stiffening; at 50 kN of tension, 50 kN at 242 mm; with none, at 252 mm. Equilibrium

The mechanism that stands up anyway

Two bars in a straight line between two pins are a mechanism by the count, by the rank and by every measure of how nearly a frame folds. Tension them and they carry load: 200 kN of tension gives the joint the stiffness of the same bars raised 1.8 degrees, and where the bars raised 3 degrees snap through at 11 kN, the tensioned flat pair carries 50 kN and goes on stiffening. The stiffness is a lack of fit of four millimetres, which 83 degrees of warmth takes away; compressed, the same pair buckles to rest crooked on one side or the other; and no tension can reach a mechanism that swings rather than shivers.

6 figures · Determinacy
The loaded end stops; the unloaded one takes over. The moments at the four floor beam ends of the frame of two 8 m bays and two 4 m storeys, its beam ends joined to the columns by end plates of 3.0 EI/L initial stiffness and 120 kN·m resistance, under λ times 20 kN/m on the left bay and 20 kN at each floor, against λ: on the softening joints (solid) and on joints that keep their initial stiffness (dashed). At λ = 1 the loaded beam's inner end carries 78 kN·m and the unloaded beam's inner end, across the same column, 13. The loaded end reaches its resistance at λ = 2.69; at λ = 3 the four ends carry 89, 120, 81, 88 kN·m, against 97, 235, 39, 68 on stiff joints. The unloaded inner end has gone from 13 to 81, 6.2 times as much for three times the load. Internal forces

The joint that softens under its own load

A bolted end plate is stiff until its moment passes two thirds of its resistance and then softens until, at its resistance, it is a third as stiff. Put such joints at every beam end of a frame under a pattern load and a push, and the most loaded joint softens first and hands its share across the column to the joint on the other side, which carries six times as much for three times the load. The redistribution grows as the frame approaches its strength. Every joint ends at its own stiffness, so the single secant stiffness an elastic analysis is allowed asks the loaded joint for half as much again as it can carry, and gives the exterior panel three quarters of what it gets.

6 figures · Corner moment
The wire's strength buys the wall. The thinnest wall, as a multiple of the bore, on which a wound tube can carry the ceiling, against the wire's strength over the liner's. Wire as strong as the liner needs 3.01; 1.2 times as strong, 2.30; 1.5 times, 1.69; from about 2.00 times, any wall. Dotted, 2.22: the thinnest wall on which shrunk-on layers of the liner's own steel reach the ceiling, where σy·ln k is twice the first-yield pressure — thinner than the same steel wound, because a layer can carry compression and a wire cannot. Materials

The wire that cannot push

A tube's liner wound with wire under tension is a compound tube of a hundred layers, each shrunk on by its own winding. It reaches the same ceiling, twice the first-yield pressure, and no further, because the bore's range belongs to the whole wall and its floor to the liner's steel. What the wire's strength decides is where the ceiling can be reached at all. A wire cannot be compressed, so a jacket of the liner's own steel needs a wall three times the bore, where shrunk-on layers of the same steel need 2.22; wire half as strong again needs 1.69; wire twice as strong reaches it on any wall. Every turn is wound harder than it will rest, by what all the turns after it take away.

6 figures · Unloading
Rigid enough long before it is a plate. A box 4.0 m wide and 2.5 m deep on a 60 m span, 45 kN/m at 2.0 m off its axis, with three diaphragms, each diaphragm of racking stiffness K, against K over the girder's own stiffness against a point distortional load, 15.0 × 10⁹ N·mm/rad: the largest warping stress (solid) and the largest distortion, which drives the walls' transverse bending (dashed), each over its value with rigid diaphragms. At ten times the girder's stiffness the warping stress is 1.05 of the rigid value and the distortion 8.37 times it; at a hundred, 0.89 and 1.50; at a thousand, 0.99 and 1.05. Marked: a cross-frame of two 1,000 mm² diagonals (26 times) and a 10 mm plate (524 times). Sections and stress

The diaphragm that is a few angles

A box girder's diaphragm holds its section square against the distortion an eccentric load drives. It does not have to be rigid; it has to be stiff against the girder's own resistance to a point racking load, which is small — twice the section's frame stiffness times its decay length. A cross-frame of two 1,000 mm² diagonals is twenty-six times that and holds the warping stress at the rigid value, while a 10 mm plate is five hundred times it. The cross-frame lets the section rack three times as far as a plate, which leaves the walls bending at 5 N/mm² instead of 1.5, against 275 with no diaphragm at all. And its diagonals carry nearly a rigid diaphragm's force whatever their stiffness, so it is sized for strength.

6 figures · Box distortion
Caught from both sides without a mode shape. The elastic critical load factor of a one-bay frame of six storeys, 3.5 m high and 6 m wide, columns of 40,000 kN·m² and beams of 60,000, 400 kN on every floor, 14.96 (level line), and the bounds the traces of its flexibility give with no assumed shape, against how many traces are taken: from below, 5.12, 10.82, 13.11, 14.07 for the first four; from above, 22.90, 19.23, 17.39, 16.39. Dotted, the storey estimate of EN 1993-1-1, 12.86, and Rayleigh's quotient on the first-order sway, 15.88. Stability

The trace that adds up every storey

A column's buckling load can be bounded from below by the traces of its flexibility, with no shape guessed. A sway frame has a flexibility too — one number per pair of floors — and its traces bound the frame's critical load factor from below and from above, closing in as more are taken: on a six-storey frame whose factor is 14.96, the first four give 14.07 to 16.39. But the first trace is Dunkerley's sum over the storeys, counting each as though its sway mode were the frame's, and it bounds a well-balanced frame worst of all: one over the number of storeys when every storey is alike, which is exactly when Eurocode 3's storey-by-storey estimate is exact.

6 figures · Stability energy
The range belongs to the truss. The worst hanger force range against the tie's largest moment in a tied arch of 100 m span and 17 m rise on 32 crossed hangers of 3,000 mm² bar, 60 kN/m of dead load and 60 kN/m of live load run on from either end, as the hangers' stiffness runs from four times a plain bar's to a fiftieth of it (dots), and for the same arch on vertical hangers (the lone dot). Softening the crossed hangers walks the bridge from 678 kN of range and 316 kN·m of tie moment to 557 and 1,154; vertical hangers sit at 194 and 3,505. The line bends nowhere near the vertical arch's point: a soft network is still a truss. Structural form

The hanger that cannot be made soft enough

A network arch's crossed hangers swing through nearly all their force as traffic passes, because they are the web of a truss. Make them softer — a spring at each anchorage — and the tie ought to take back some of the shear and the hangers' ranges ought to fall. They hardly do. A tenth of the stiffness takes 6 per cent off the worst range and adds a third to the tie's bending; a fiftieth takes 18 per cent off and multiplies the tie's bending by 3.7. The range belongs to the truss and leaves only when the truss does, which vertical hangers show at 194 kN against 678 and eleven times the bending. So the hanger is sized for its range, eight times the area its strength needs, and the stiffness that comes with it costs the range nothing.

6 figures · Network arch
Shorter after every cycle, at the same load. The shortening of a column hinge at the end of each cycle, in yield strains, for an I-section of 3,000 mm² and 200 mm depth and the rectangle of the same area, each carrying a constant 30% of its squash load while its curvature cycles between ±3.0 times its first-yield curvature, in elastic–perfectly plastic steel. The I-section shortens by 8.14 yield strains every cycle, 97.1 after 12; the rectangle by 1.60, 19.4. Neither settles: the load has not changed, and the column is shorter after every cycle. Materials

The column that shortens on every cycle

A column hinge bent back and forth by an earthquake carries its share of the building's weight the whole time. In elastic–perfectly plastic steel an I-section at three tenths of its squash load, cycled to three times its first-yield curvature each way, comes back from every cycle shorter by eight yield strains, and goes on doing so: it never settles. The flange that yields in compression shortens, and the other flange, carrying its part of the column's load, never reaches yield in tension to pull it back. A rectangle of the same area shortens a fifth as fast, and the overturning that swings the column's load up and down hardly matters. The weight and the curvature make the ratchet between them.

6 figures · Moment-curvature
The knee moves out as the braces multiply. The critical load of a pin-ended column, over the Euler load of the segments between its braces, against the braces' stiffness in units of that load over the segment's length, for one, two and four braces. Each curve rises to the segment's Euler load and stays there; the knee where it arrives is at 2.00, 3.00, 3.62. With no braces at all the column buckles at 1/(n + 1)² of the segment's load: 0.25, 0.11, 0.04. Stability

The braces that have to hold each other

One brace at mid-height must have a stiffness of twice the column's load over the length it halves. Spread the same column over four braces and each one must be stiffer, not softer: 3.62 times the load over its segment, rising towards four with every brace added, because the shape the braces have to stop is a zigzag in which every brace point is pushed by both its neighbours. Braces that tie the column to itself instead of to the ground need one, however many there are. A row with surplus stiffness can carry one brace at two thirds of the ideal, but not one that is missing, and the force each brace has to resist grows with the count.

6 figures · Effective length
Whole spans miss the shear inside a span. The shear along three spans of 8.0, 8.0, 8.0 m, under 20 kN/m of dead load everywhere and 15 kN/m imposed: the largest and least when the imposed load stands wherever it raises or lowers the shear at each section (solid), and when it may only cover whole spans (dashed). At the supports the two agree. At the middle of the second span the exact envelope reaches 23.8 kN either way and the whole spans 10.0 kN; at a tenth of the way along it, 122.4 against 122.0. Internal forces

The shear whole spans cannot find

A continuous beam is designed by loading its spans in patterns, whole spans at a time, and for the bending moment that is very nearly exact: the moment's influence line keeps one sign over each span, so a span is either worth loading or not. The shear's influence line changes sign at the section itself, inside the span, and no pattern of whole spans can load one side of a section and not the other. At the middle of the inner span of three equal spans the imposed shear is 0.198 qL; whole spans find 0.083 qL, and the straight line to qL/8 that is safe on a simple span finds 0.125.

7 figures · Influence line
A crack starts at the corner and runs along the grain. The end of a timber beam 400 mm deep and 140 mm wide, notched on its underside so that 200 mm stands over the support, with the notch's corner 50 mm from the line of the reaction, drawn to scale. A crack starts at the corner and runs along the grain towards mid-span. With a shear strength of 3.5 N/mm² the un-notched end would carry 130.7 kN; Eurocode 5's factor kᵥ of 0.40 on the reduced depth leaves 25.8 kN, 20% of it. Sections and stress

The notch that costs more than its depth

Cut a timber beam's underside away at the support, so that half its depth sits on the bearing, and a stress check on what is left says the end has lost half its shear strength. The beam says otherwise. A crack starts at the notch's corner and runs along the grain, and whether it runs is a question of energy, not stress — so the answer has a size in it. A 400 mm glulam beam notched to half its depth keeps a quarter of its shear resistance, an 800 mm one keeps 18 per cent, and the deeper the beam the less a notch leaves. Sloping the notch buys much of it back, and moving the corner away from the support costs it again.

6 figures · Shear flow
Double the span and the deck is nearly three times nearer buckling. The factor on its own dead load at which a stayed deck buckles, against the main span, on logarithmic axes, for a deck of 0.50 × 10¹² N·m² under 150 kN/m with stays every 15 m from towers 0.40 of the half-span tall. At 300 m it is 40.7; at 600 m, 14.7; at 1,000 m, 6.9; at 2,000 m, 2.3. Beyond 600 m the line falls with a slope of 1.53; it crosses ten, below which a design has to follow the deck's deflections into its forces, at 805 m. Structural form

The deck the stays squeeze

Every stay of a cable-stayed bridge pulls the deck towards its tower, and the deck carries all those pulls as a compression that is largest at the tower — 95 MN in a 1,000 m span under 150 kN/m. The stays hold it up and hold it straight, as springs under a strut. The compression grows with the square of the span and the springs soften with it, so the factor on its own weight at which the deck would buckle falls as the span to the power one and a half: 41 at 300 m, 6.9 at 1,000 m, 2.3 at 2,000 m. A deck four times stiffer only doubles it, and the long stays' sag, which softens them for traffic, hardly enters.

6 figures · Stiffening girder
A screen damps a tank on a tower and barely touches a standpipe. The rms drift under broadband ground shaking, as a share of the same structure with its water frozen to the wall, against the damping a screen gives the sloshing: a steel standpipe 10 m across and 30 m tall with a 12 mm shell, full (solid), and the water tower of the earlier essay, a 12 m tank 8 m deep on a tower of 2.5 s (dashed). Plain water, at half a per cent: 0.82 and 1.01. A screen giving 10%: 0.76 and 0.40. The standpipe's gain comes almost entirely from leaving the lens out of the shaft's motion, which plain water already does. Dynamics

The tank that is its own tower

A standpipe holds its water in its own shaft, so the water fills a height several times its width. Only a lens of it near the surface sloshes — 0.455ρπR³, 178 t of the 2,199 t in a steel standpipe 10 m across and 30 m tall — and that lens stops growing once the water is deeper than a radius, so its period is set by the width alone: 3.3 s, against the shaft's 0.38. The lens is 8% of the water but a quarter of the shaft's moving mass, because it sits where the shaft moves most. It is far too slow to be tuned as a damper, and a screen can do little with it; what it does instead is stay still while the shaft sways, which takes nearly a fifth off the drift a frozen-water calculation predicts.

6 figures · Sloshing
A quarter of the visits shared uses up the whole reduction. The factor needed by 20 floors carrying office imposed load — a sustained part of mean 0.50 kN/m² renewed every five years on average, and visits of mean 0.2 kN/m² arriving 0.3 times a year on each floor for three days, against the share of the visits made by the whole building at once: floors let singly (solid) and to one tenant (dashed), and the storey rule's 0.73 (dotted). With no share, 0.26 and 0.60; with a tenth, 0.51 and 0.67; with a quarter, 0.68 and 0.75; with all, 0.96 and 0.97. The rule's factor is reached at a share of 0.34 let singly and 0.21 to one tenant. Equilibrium

The visits that come to every floor at once

A floor's characteristic imposed load is set mostly by its worst visit — a party, a move, a crowd — and visits to different floors almost never coincide, which is why a column carrying twenty office floors needs only about a quarter of their summed loads. Let some of the visits be made by the whole building at once and nothing changes on any one floor; one floor cannot tell. The column can. A tenth of the visits shared takes the twenty-floor factor from 0.26 to 0.51, a quarter to 0.68, and a third uses up the whole of the storey rule's reduction. The rule fails in exactly the buildings whose use synchronises the crowd, and it fails most where the load mostly visits.

6 figures · Live load reduction
Allowed to yield, the damaged truss is hardly lighter. The steel in an eight-panel Pratt truss with a counter-diagonal in each interior panel, loaded by 10 at every bottom joint, sized to survive the loss of any one interior diagonal, against the share of the full load it must carry with the diagonal gone: checked elastically (solid) and by the lower-bound theorem, every member allowed to yield (dashed); the intact design's 1,200 as a level line. At a third, 1,221 elastic and 1,206.7 plastic; at two thirds, 1,304 elastic and 1,296.7 plastic; at the full load, 1,555 elastic and 1,545.0 plastic; at four thirds, 2,074 elastic and 2,060.0 plastic. The plastic design saves 7.4 units at two thirds of the load out of the 104 that robustness costs. Deflection

The section that yielding cannot reach

A truss that loses a member in an accident is allowed to yield while it finds another way to stand, so a counter-braced truss sized by the lower-bound theorem ought to need far less steel than one sized elastically. It needs 1,296.7 units against 1,304 — seven of the 104 that robustness costs. One diagonal gone, the damaged panel is determinate at its own section, and no redistribution can change a force a cut decides; yielding can reach only the verticals. What does move the price is a counter that buckles: good for half its tension in compression, it adds 120 units, more than robustness did.

7 figures · Truss deflection
The preload a storm can live with, raised by a spring under the nut. The largest preload the bolts of a 500 × 400 × 20 mm base plate with two M24 holding-down bolts in each of two rows can be given and come out of a storm without stretching, against the stiffness of a stack of disc springs under each nut, for storms to ±165, ±170, ±175 kN·m; dashed, the same for the bare base; dotted, the bolt's yield of 226 kN. To ±170 kN·m the bare base keeps at most 128 kN; with a stack of 500 kN/mm, 150; 100 kN/mm, 187; 20 kN/mm, 214; 5 kN/mm, 223. Connections

The spring under the nut

Retightening a column base after every storm makes its bolts ratchet, because a storm can only live with 128 kN of preload and the spanner keeps putting back 150. A stack of disc springs under each nut changes what the storm can live with. Soft enough, the bolts never reach their yield: the compression side keeps its preload, the bed's resultant moves out to the plate's edge, and the moment rides on lever arm rather than on bolt force. A stack as stiff as the bolt itself keeps 150 kN through every storm. Much softer, and the storm the bolts no longer feel lands on the grout.

7 figures · Base plate
The best compensation is less than the prediction. For every floor of a 40-storey building of 3.6 m storeys, its perimeter columns at 12 N/mm² and its core at 6 under the finished load, cast a floor every seven days, with 25 per cent of the load arriving as finishes 90 days after the frame is complete and creep coefficient 2.2, from its fit-out to thirty years, with the creep anywhere within ±30 per cent of the design value: the largest amount any floor stands high (dashed) and stands low (light), and the worse of the two (solid), against the share of its predicted thirty-year movement each floor is set high by. Uncompensated, a floor ends 31.9 mm low; compensated in full, a floor stands 16.0 mm high at its fit-out; the worst is smallest, 11.0 mm, at 0.79 of the prediction, where level 40 standing high 0 days after its fit-out under creep ×0.70 balances level 33 standing low after thirty years under creep ×1.30. Deflection

The floor that is level on one date

Each floor of a tall concrete building is set high by the amount its columns are predicted to drop against the core, so that it arrives level. Counted in time, the drop does not peak at mid-height and stop at the roof: the worst floor of a forty-storey building is level 31, the roof moves 24 mm, and half the movement is still to come when the floors are fitted out. Set high by all of the prediction, a floor is level on one date thirty years away and 16 mm high at handover. With the creep known to ±30 per cent, setting it high by about four fifths of the prediction makes the worst floor's error 11 mm instead of 16. And none of it changes what the partitions see.

6 figures · Differential shortening
The pair holds its clamp longer than the stub it is checked by. The tension a bolt at which the clamp lets go, as a share of the 110 kN preload, against the end plate's lever arm from web to bolt, for an end plate 18 mm thick on a column flange 14 mm thick at 30 mm: the pair (solid), the end plate's stub (dashed) and the column flange's (dotted). With the end plate's bolt at 30 mm the pair and the stubs nearly agree. At 45 mm the pair lets go at 88.2 kN and the end plate's stub already at 81.1, the pair holding 9 per cent more; at 60 mm, 82.0 against 71.2, 15 per cent more. Connections

The clamp the pair holds longer

A preloaded bolt clamps an end plate to a column flange, and the joint stays closed until the tension relieves the clamp. The joint diagram says that happens at the preload over one minus the bolt's share — 122 kN for a 110 kN preload — but prying adds to the tension at the bolt line and the clamp lets go at 88. A component model checks each flange as a stub on a rigid base and lets the joint go when its weaker stub does, at 81 kN. The real pair, its tips leaning on a column flange that gives way, pries less than the end plate alone would, and holds its clamp nine per cent longer — fifteen when its lever arms are two to one.

6 figures · Prying
In a core, the depth has to tune the tank, and only shallow water is slow. The sloshing period of rectangular tanks 6, 10, 15 m long against the depth of their water (logarithmic), with building periods of 4, 5, 6 and 8 s (dotted). Deep, each tank is as fast as it can be: 2.77 s, 3.58 s, 4.38 s. To be tuned to a 5 s building the 10 m tank needs 1.80 m of water; to 4 s, 3.50 m; to 8 s, 0.65 m. A building faster than 3.58 s cannot be reached by the 10 m tank at any depth. Dynamics

The tank that must be shallow to be slow

A deep tank's sloshing period is set by its width alone, so a tank in a tall building's core ought to be tuned by choosing how wide to make it. It cannot be. A deep tank fast enough to fit is too fast for the building: 3.6 s for a core 10 m across, where a 5 s building would need a tank 19.5 m long and an 8 s one 50 m. The depth has to tune it, and only shallow water is slow — 1.73 m for 5 s, 0.63 m for 8. Shallow water is the efficient kind, with four fifths of it sloshing. But at the accelerations the tank exists to reduce, the wave it makes is a quarter of its depth on a 5 s building and seven tenths on an 8 s one, and the linear tuning it was designed by has stopped describing it.

6 figures · Sloshing
The pressure on the wall jumps where the bin meets the hopper. The normal pressure on the wall of a bin 8 m across holding 30 m of a solid weighing 9 kN/m³, wall friction 0.45 and K = 0.45, over a conical hopper of half-angle 20° with wall friction 0.40, the solid's internal friction 35°, down the bin and then down the hopper: in the bin, K times Janssen's vertical stress (solid) and that times the 1.35 discharge factor (dotted); in the hopper, filling (light) and emptying (dark). At the foot of the bin the wall carries 38.1 kPa, 51.4 with the discharge factor. On the hopper's top edge it carries 75.8 kPa filling and 95.7 emptying — 1.99 and 2.51 times the bin wall's. Half way down the hopper, 46.3 and 36.7 kPa. Equilibrium

The pressure that switches at the hopper

Below a silo's bin a conical hopper funnels the grain to its outlet, and the wall pressure there does not keep growing with depth as a liquid's would. It peaks at the hopper's top edge. Filling, the edge carries twice the bin wall's pressure just above it; emptying, the grain converges on the outlet, its largest stress turns from vertical towards horizontal, and the edge carries two and a half times. Half a metre above the apex the stress is 2.6 kPa whether the bin holds 5 m of grain or 60 — which is why a silo empties at the same rate full or nearly empty.

6 figures · Silo pressure
The order of building decides which supports keep the secondary moment. The secondary moment at each interior support of a five-span beam of 16 + 16 + 16 + 16 + 16 m prestressed with 2,400 kN on a parabolic tendon, built and stressed from one end, from both ends towards a closure bay, from the middle outwards, and all at once. From one end: 161, 175, 160, 219 kN·m; from both ends: 161, 172, 172, 161 kN·m; from the middle out: 215, 120, 120, 215 kN·m; all at once: 344, 258, 258, 344 kN·m. Internal forces

The beam built towards its own middle

A continuous prestressed beam built one bay at a time from one end keeps about half the secondary moment a beam stressed at once would carry, and most of it at the end where it was finished. Built from both ends towards a closure bay, it is symmetric, and the closure's supports keep only a little more than the rest: 172 kN·m against 161. Built from the middle outwards, the first interior supports — the ones the load hogs hardest — keep 215, 63 per cent of the at-once value, for any length of beam. The order of construction is a design variable. Creep then takes back most of the choice.

6 figures · Secondary prestress
Past yield, the notch trades stress for strain. The root of a notch of elastic factor 3.0 in a mild steel whose cyclic curve reaches 0.2 per cent strain at 252 N/mm², under a nominal stress of 200 N/mm²: the cyclic stress–strain curve (solid), the elastic line the root would follow if it stayed elastic (thin), and Neuber's hyperbola σε = (KₜS)²/E (dashed), which the curve crosses at the root's state. Elastic, the root would carry 600 N/mm² at 0.30 per cent. By Neuber it carries 293 at 0.61 per cent; by Glinka's energy rule 272 at 0.44; by the linear strain rule 246 at 0.30. Materials

The notch that trades stress for strain

A notch with an elastic factor of three triples the stress at its root only while the root stays elastic, which in a mild steel is up to a nominal stress of about 84 N/mm². Past that the root's stress and strain part company: at a nominal 200 the root carries 293 N/mm², not 600, and strains 0.61 per cent, twice what the elastic factor implies. Neuber's rule and Glinka's bracket the truth a factor apart, and in the low-cycle range that factor is a factor of two in life. The trade has two gifts in it: one overload leaves the root in compression, and a mean stress mostly yields itself away.

6 figures · Stress concentration