The collection

Every essay — page 22

Essays 505 to 528 of 785, in the same order.
Three members after a diagonal goes. The forces in three members of the counter-braced truss when the diagonal 9–2, carrying 242 kN, is removed instantaneously, with 2 per cent damping, over one and a half of the damaged truss's first periods (0.57 s); dashed, the static force each settles to. The counter-diagonal 1–10 goes from −112 kN to −354 kN and peaks at −491 kN, 1.57 times its change. The bottom chord 3–4 ends exactly where it started, 750 kN, and on the way peaks at 1,115 kN. The bottom chord 2–3 settles lower, at 556 kN, after a first swing the other way, to 905 kN. Structural form

The factor of two belongs to one mode

A member that fails suddenly hands its force to the structure around it all at once, and the convention is to double the static answer: a load applied suddenly to a spring overshoots to twice its static deflection. A truss is not one spring. Take a diagonal out of a counter-braced truss in an instant and some members swing to three times their change of force, one swings the wrong way first, and a bottom chord whose force does not change at all passes through half as much again as it carries — because every mode overshoots by two, at its own time, and a member is a sum of modes.

5 figures · Robustness
A soft layer over stiff ground, and a moment neither has. The bending moment down a 20 m pile of bending stiffness 120 MN·m² with a free head, pushed sideways by 150 kN (its characteristic length in ground at 5.00 MN/m³ being 1.89 m), in three grounds: all of it at 5.00 MN/m³; all of it at 0.50 MN/m³; and soft ground 2.0 characteristic lengths (3.8 m) thick over the other (dotted: the interface). The largest moments are 219 kN·m, 346 kN·m and 427 kN·m; the head deflections 20.4 mm, 81.4 mm and 61.6 mm. The layered ground gives a larger moment than either ground on its own: the pile bends as a pile in the soft layer would, and then meets ground that holds it. Internal forces

The layer a pile feels

A pile pushed sideways in uniform ground has one characteristic length, the fifth root of its stiffness over the ground's, and every answer is a multiple of it. Put a soft layer over stiff ground and that length stops existing. The head feels the top of the ground in proportion to the square of its own deflection, so an average weighted that way gets the head deflection within eight per cent. It gets the moment a quarter too low: with soft ground two characteristic lengths thick over stiff, the pile bends harder than it would in either ground alone, and the peak sits where the stiff ground takes hold.

6 figures · Lateral pile
Three grounds, three tipping pushes. The push against the lean it produces, in thousandths of a radian, for the 6 m square, 3,000 kN block on ground that bears 300 kPa at most, half of it mobilised at 7.5 mm of settlement, pushed 8 m up, its weight 5.0 m up, on the three grounds matched at their limit and at half of it; dashed, the rigid-plastic limit, 813 kN. Linear, capped: 776 kN at a lean of 13.2 thousandths; hyperbolic: 701 kN at a lean of 26.2 thousandths; S-shaped: 770 kN at a lean of 15.2 thousandths. The S-shaped ground behaves almost exactly like the capped one; the hyperbola, which never quite reaches its limit, tips 10 per cent sooner at twice the lean. Equilibrium

The ground that never quite gives way

On a bed of springs capped at the ground's bearing limit, a block pushed sideways tips at a definite push, below the limit the rigid-plastic parabola gives. Real ground is curved: it softens all the way to its limit and never quite reaches it. On such ground the block has no tipping push of its own. Its resistance creeps toward the limit, and the peak it does have is made by its own weight leaning with it — 14 per cent below the limit with the weight 5 m up, nearly at it with the weight at the base, where the lean simply runs away.

5 figures · Overturning
What the actuator pushes against decides its limit. The largest feedback gain, as the damping it would add to the bare mode, at which the loop stays stable, against the delay as a fraction of the period, on a logarithmic scale, for a mode of 1.00 per cent damping carrying a tuned mass of 2.00 per cent of its modal mass at Den Hartog's tuning. Pushing against the ground, fed by the structure's velocity: 2.41 at a delay of 0.05, 0.25 at 0.2. Pushing against the tuned mass, fed by the same velocity: 0.0156 at almost no delay, rising to 0.091 at a quarter of a period. Pushing against the tuned mass, fed by the velocity across it: unlimited with no delay, 0.048 at 0.05, 0.0073 at 0.2. Dynamics

The actuator that pushes against the mass

An actuator that damps a structure by feeding back its velocity has to push against something. Against the ground, it is stable up to large gains until a delay of a quarter period removes its damping. Against a tuned mass — the arrangement meant to keep a passive damper underneath — the same feedback goes unstable at a gain of a per cent and a half with no delay at all, makes the structure worse than the passive mass at every gain below that, and drives the mass three or four times as far. What limits it is not when it acts but what it pushes against.

5 figures · Tuned mass damper
A column curve with no plateau. The tangent-modulus buckling stress of perfect pin-ended columns of an aluminium alloy of 0.2 per cent proof stress 250 N/mm² and modulus 70,000, as a share of the proof stress, against the slenderness λ̄ — the square root of the proof stress over the Euler stress — for Ramberg–Osgood exponents of 5, 10, 20 and 40; dashed, the sharp envelope a material with a plateau at the proof stress would give, the lesser of the proof stress and Euler's. n = 5: 1.54 at λ̄ = 0.2, 0.66 at 1, 0.41 at 1.5; n = 10: 1.16 at λ̄ = 0.2, 0.74 at 1, 0.45 at 1.5; n = 20: 1.04 at λ̄ = 0.2, 0.82 at 1, 0.45 at 1.5; n = 40: 1.00 at λ̄ = 0.2, 0.88 at 1, 0.45 at 1.5. Stocky columns buckle above the proof stress, because the curve goes on rising past it; slender ones follow Euler; in between every curve sags below the envelope. Stability

The column with no plateau

A steel column's curve is the lesser of two lines, its yield stress and Euler's, because mild steel keeps its whole stiffness up to yield and then has a plateau to stop on. Aluminium and stainless steel have no plateau: their stiffness starts falling well below the proof stress and never stops. Their column curves are not the steel curve moved; they are a different shape — four tenths below the corner for a stainless steel, above the proof stress for a stocky column — and the shape is set by two numbers, only one of which describes the knee.

6 figures · Inelastic buckling
How far a local load spreads, and what is nearest its limit. Along a steel-faced polyurethane cladding panel, 0.5 mm faces of 320 N/mm² steel on an 80 mm core crushing at 0.12 N/mm², from the middle of a strip load of 3.0 N per mm of width spread over 10 mm: the face's deflection over its value under the load, the core's compressive stress over its crushing strength, and the face's bending stress over its yield stress. The load spreads over a length set by the fourth root of the face's bending stiffness over the core's, 1/β = 20.5 mm; the deflection is 1.44 mm under the load and changes sign beyond 48 mm. The core is at 0.60 of its crushing strength and the face at 0.89 of its yield stress: this panel's face yields at 3.36 N/mm and its core crushes at 5.00. Sections and stress

The face that dents and the core that crushes

A sandwich panel carries bending as a couple between its faces, and that is a calculation about the whole panel. Put a local load on one face — a foot, a fixing, a dropped tool — and the face becomes a thin beam on a soft bed, spreading the load over a length the fourth root of their stiffnesses sets. Then either the face yields and dents, or the core crushes beneath it, and which comes first is decided by one thickness: below it the face gives, above it the core does, and a steel-faced roof panel is on the wrong side of it for anyone who walks on it.

5 figures · Sandwich section
A deck holds the middle of the span. The twist along an 8 m open section on forks, free to warp, carrying 12 kN/m at 75 mm from its shear centre — 900 Nmm of torque per mm of span. With nothing fastened to it the beam twists 6.25° at mid-span; a deck resisting the top flange's rotation at 5.0 kNm per metre per radian holds it to 4.20°, and one four times as stiff to 2.10°. The deck works where the beam is weakest, in the middle; near the supports the beam's own torsional stiffness does most of the work whatever is fastened to it. Deflection

A deck is a spring, not a wall

An open-section beam loaded off its shear centre twists, and the usual reassurance is that the deck fastened to its top flange will stop it. The deck resists the flange's rotation with a stiffness per metre of span, and that stiffness has to be compared with the beam's own. On an 8 m beam a screwed deck of ordinary stiffness removes a third of the twist; on a 16 m beam the same deck removes three quarters, because the beam's torsional stiffness falls with the square of its span and the deck's does not.

6 figures · Twist serviceability
Ductile until it was welded. A 2.0 m 6082-T6 member pulled in tension, as supplied and with one weld across it whose heat-affected zone is 60 mm long: the load per unit of parent section against the member's overall strain, to the maximum load, where the weaker part begins to neck. The plain member reaches 310 N/mm² at 7.0% strain, 140 mm of stretch. The welded one reaches 185 N/mm² at 0.62%, 12.3 mm — 8.8% of the plain member's, and the parent never reaches its proof stress of 260 N/mm². (uniform elongations assumed: 7.0% for the parent, 12% for the zone) Materials

The soft zone that takes all the stretch

The metal beside a weld in heat-treated aluminium is weaker than the rest of the member and more ductile, and it is tempting to read the second fact as a consolation. It is not. A member welded across stretches only where it is weak, and the weak zone is sixty millimetres long; a two-metre 6082-T6 tie that would extend 140 mm before necking extends 12 mm once welded, and the parent metal never yields at all. What decides it is one ratio, the zone's ultimate strength over the parent's, and the ductility returns only when that ratio reaches one.

6 figures · Heat-affected zone
The modes that tilt, and the ones that do not. Johansen's mechanisms for a 12 mm bolt with washers in single shear through 40 and 40 mm of timber of density 350 kg/m³, each with the rope term the fastener's axial resistance of 6.64 kN adds to it. Modes a and b, where the fastener only translates, gain nothing; the modes in which it tilts gain a quarter of its axial resistance, capped at a quarter of their own Johansen value. The joint's capacity rises from 5.02 kN (mode c) to 6.28 kN (mode c), 25 per cent. Connections

The pull that Johansen left out

Johansen's mechanisms treat a timber fastener as a beam in a bed of crushing wood, bent and pushed sideways and nothing else. A real fastener that tilts across the joint is also pulled along its own axis, and if a washer or a thread resists the pull, it clamps the two members together and adds to what the joint can carry. The addition is a quarter of the axial resistance, it goes only to the modes in which the fastener tilts, and it is capped by fastener type — nothing for a dowel, a quarter for a bolt, all of it for a screw — which is how a screw keeps gaining strength past the thickness at which Johansen's capacity stops.

6 figures · Dowel yield
The chimney that locks in most is tuned above the commonest wind. Lock-in cycles a year at the full lock-in amplitude that do the same damage as the whole band (millions), for 1.2 m cylinders of every frequency in hourly mean winds at the top Rayleigh-distributed with scale 5.5 m/s, against the critical speed as a multiple of that scale. Solid, the count through the amplitude envelope; dashed, EN 1991-1-4's closed form 2·T·f₀·ε₀·(Ucr/v0)²·exp(−(Ucr/v0)²) at band widths ε₀ of 0.1 and 0.3. All three peak at a critical speed of √(3/2) = 1.22 times the scale, 6.7 m/s — above the commonest wind (0.71) and the mean (0.89). The envelope is EN's formula with ε₀ = 0.22. The chimney drawn, at 6.0 m/s, collects 4.6 million a year. Dynamics

The breeze that uses up a chimney

A chimney that locks in to vortex shedding at a breeze is usually told to accept the motion and check its fatigue. Counting the cycles a real wind climate delivers turns that into arithmetic, and the arithmetic has two surprises. The chimney that collects the most cycles is not the one tuned to the commonest wind but to one a fifth stronger than the climate's scale, so stiffening a chimney can shorten its life. And damping does not lengthen the life in proportion: it ends the count, all at once, at the damping that puts the largest stress range under the detail's cut-off.

7 figures · Vortex-shedding
Every one of these soils failed that slope. For a 10 m slope at 35° in soil of 19 kN/m³ with a pore pressure ratio of 0.25, over a firm stratum 5 m below its toe, which has slipped: the pairs of effective cohesion and friction angle that put its critical circle at a factor of safety of exactly one, by Bishop's method. At no friction the cohesion is 32.1 kPa; at 20° it is 12.4; at 40°, 2.0; and the line reaches no cohesion at 48.1°, where a skin of soil slides parallel to the face. Labelled, the depth of each pair's slip below the original ground: 13.6 m at 0°, 8.8 m at 5°, 7.4 m at 10°, 5.2 m at 20°, 3.6 m at 30°, 2.3 m at 40°. Equilibrium

A failed slope gives a line, not a soil

A slope that has slipped is the one full-scale strength test geotechnics ever gets, and the standard way to read it is to set its factor of safety to one and solve for the soil. One equation cannot give two strengths. What it gives is a line of cohesions and friction angles, every one of which fails the slope exactly, and the repair designed on one point of that line can be worth a factor of 1.07 or of 1.51. The slip itself says which point: each soil on the line fails along a different surface, and the depth of the scar is the second equation.

6 figures · Slope stability
The interior panel is designed by the case that designs nothing else. The shear across the column-web panel at each kind of joint of a frame of two 8 m bays and two 4 m storeys with fixed bases, 457 mm beams and 254 mm columns with 8.6 mm webs, under five load cases, the worse direction of sway taken where there is one. Full gravity: roof corner 106, roof interior 0, floor exterior 143, floor interior 0 kN; One bay loaded: roof corner 115, roof interior 117, floor exterior 150, floor interior 154 kN; Sway: roof corner 25, roof interior 40, floor exterior 53, floor interior 89 kN; Gravity + sway: roof corner 131, roof interior 40, floor exterior 196, floor interior 89 kN; Pattern + sway: roof corner 141, roof interior 157, floor exterior 203, floor interior 242 kN. The floor interior panel is empty under full gravity and carries 89 kN under gravity with sway, the case that governs the members; under one bay loaded with sway it carries 242 kN — 2.7 times as much, more than any exterior panel's 203 kN, and 70 per cent of the web's shear resistance. Internal forces

The panel that gravity leaves empty

A corner joint's panel carries the difference between a beam's flange couple and half a column's shear, and full gravity load is what makes that large. An interior joint has a beam on each side, and under full gravity their two couples cancel: the panel between them carries nothing at all, in the load case that sizes every member around it. It fills under the two loads that are not symmetric. A pattern load hands it one beam's moment, and sway hands it two beams' moments turning the same way. Together they put more shear through it than through any exterior joint, in a combination that governs no member.

7 figures · Corner moment
More props, heavier slabs — unless they go in after the weight. The heaviest load any slab carries during construction, as a multiple of its own weight, against the number of levels of props under the slab being cast. Every level a shore that carried the wet concrete and moves up with the formwork: 2.00, 2.25, 2.37, 2.44 w for one to four levels. One level of shores and the rest backprops, put in snug after the formwork is struck: 2.00, 1.50, 1.33, 1.25 w. The same number of props, differently timed: a shore enters the load path before the weight it carries and passes it down, and a backprop enters after and shares only what arrives later. Materials

Loaded twice over before it is a month old

A concrete floor in a building going up a storey a week carries, in its first weeks, the wet weight of the floors being cast above it, handed down through the props. By Grundy and Kabaila's arithmetic that is twice its own weight on a single level of shores, and more with more levels — 2.25 on two, 2.37 on three — because every prop that carried wet concrete passes its load down the stack. The same props put in after the formwork is struck carry nothing until something new arrives, and the peak falls to 1.5, 1.33, 1.25. The heaviest day of a floor's life is decided by when its props went in, not how many there are.

6 figures · Maturity
What the fillets are worth across the section tables. For seven standard rolled sections, the torsion constant the film gives over the rolled outline, beside the published one (UB 203×133×25 5.96 against 5.96 cm⁴; UB 305×165×40 14.74 against 14.70 cm⁴; UB 457×191×67 37.14 against 37.10 cm⁴; UB 610×229×101 76.97 against 77.00 cm⁴; UC 152×152×23 4.63 against 4.63 cm⁴; UC 254×254×73 57.68 against 57.60 cm⁴; UC 305×305×97 91.22 against 91.20 cm⁴). Solid bars: what the fillets add to J over the same plates with sharp corners, 9 to 13 per cent. Second bars: how far the fillet's peak stress exceeds the flange face's, 45 to 65 per cent. Σbt³/3 is 7 to 12 per cent below the published constant. Sections and stress

The corner the rolling mill rounds

The torsion constant of an I-section is taught as Σbt³/3, the sum over three thin plates, and a rolled section is not three plates. Where its web meets each flange the mill leaves a fillet, a curve of steel about one per cent of the section's area, and the soap film whose volume is the torsion constant rises into it. Solved over the real outline, the film reproduces the published constant of seven standard sections to a fifth of a per cent and says the fillets are worth nine to thirteen per cent of it. It also puts the section's largest torsional stress on the fillet, half as much again as the flange formula every design check uses.

5 figures · Torsional constant
Wrong in both directions until the building racks. Across buildings from a pure bending tower to a pure racking frame (αH on a logarithmic scale), each 20 storeys with gravity putting its own critical factor at 5.0: solid, the least storey sway factor over the building's own, which is what taking the least storey as the building's costs; dashed, the ground storey's second-order increase estimated from its own sway factor, over the true increase. At αH = 0.1 the least storey factor is 0.77 of the true one and the ground storey's estimate 0.09 of the true increase; at αH = 10, 0.86 and 0.37; at αH = 100, 0.94 and 0.98. The first error is on the safe side and the second is not, and both vanish only for a building that racks. Stability

The storey that cannot see the building lean

A sway check made storey by storey asks each storey how much it drifts under a push and how much gravity sits on it, and reads a critical load factor for the storey from the two. For a frame whose storeys rack like a stack of shelves that is exact. For a building that bends — a braced core, a wall — it is wrong twice. Taking the least storey as the building's reads a critical factor of 3.9 for a building whose own is 5. And amplifying each storey by its own factor finds a 2 per cent second-order increase at the ground storey, where the truth is 20, because the ground storey hardly drifts and carries the lean of everything above it.

6 figures · Sway stability
The ratio stops growing and the twist does not. For a 30 × 18 m floor with a torsional radius of 10.6 m (0.35 of its length), against the distance of the centre of rigidity from the plan's middle as a share of the length, with the accidental eccentricity of 5 per cent of the plan: solid, the codes' ratio of the worst edge's displacement to the average of the two edges; dashed, the worst edge's displacement over the translation of a plan with no eccentricity. Dotted, the thresholds 1.2 and 1.4. The ratio rises to 1.76 at an eccentricity of 0.30 of the length and then falls, to 1.72 at 0.45; the edge's movement rises the whole way, from 1.20 to 4.83. The core-and-façade plan, at 0.14, reads 1.63 and moves 1.98. Structural form

A measure of twist that divides by the twist

The seismic codes decide whether a building is torsionally irregular by one ratio: the worst edge's displacement over the average of the two edges'. For a plan with no natural eccentricity that ratio is exactly how much further the corner moves than a plan without torsion would. For an eccentric plan it is not, because the twist moves the average as well as the corner, and the ratio divides one by the other. It saturates: at a torsional radius a third of the plan's length it never passes 1.76, however far the stiffness is moved off-centre, while the corner's movement keeps growing past four times. Past a point a more eccentric plan reads more regular, and the amplifier the codes build from the ratio inherits its ceiling.

5 figures · Plan torsion
What the frame notices. An 8 m by 4 m portal whose columns stand on bases of every rotational stiffness, in units of the column's EI/L on a logarithmic scale: solid, the portal's sway under a load at the knee as a multiple of the fixed-based portal's; dashed, the columns' effective length factor in sway (fixed bases 1.13, pinned 2.26). Bolts sleeved 300 mm, 5.3 EI/L: 1.45 times the fixed portal's drift, an effective length factor of 1.30 and 75 per cent of its buckling load; as detailed, 9.1 EI/L: 1.28 times the fixed portal's drift, an effective length factor of 1.23 and 83 per cent of its buckling load; rigid by EN 1993-1-8, 30.0 EI/L: 1.09 times the fixed portal's drift, an effective length factor of 1.16 and 94 per cent of its buckling load. Connections

The fixed base the bolts decide

A column base drawn as fixed is a spring, and the component method says what it is made of: the grout squeezed under the flange, the plate bending under the bolt row, and the anchor bolts stretching over their free length. For a 500 mm plate on two M24 bolts the bolts are three fifths of its flexibility, so the base comes out at nine times the column's EI/L — under a third of what EN 1993-1-8 calls rigid — and no thickness of plate can lift it above fifteen. Leave the bolts free in sleeves for erection tolerance and it falls to five. The frame on it drifts 28 per cent more than a fixed-based one and buckles at 83 per cent of the load.

5 figures · Base plate
What a millimetre on each member does at mid-span. A Pratt truss of eight panels, 24.0 m long and 2.4 m deep, carrying 60 kN of dead load at each top node, drawn with its depth exaggerated. Each member is drawn as thick as, and labelled with, the distance mid-span moves for a millimetre's change in that member's length: its force under a unit load at mid-span. The middle top-chord members move it 2.50 mm per mm — the span over four depths — and the chord members fall off towards the supports: 1.25, 1.88, 2.50, 2.50, 1.88, 1.25 along the top chord. The diagonals move it 0.80 per mm and most verticals 0.50; three verticals — the one at mid-span and the two beside the supports — carry nothing under a load at mid-span and move it not at all (dashed). A truss's shape is its members' lengths, weighted like this. Deflection

The camber that lives in the member lengths

A beam is cambered by bending it; a truss cannot be, because it has no curvature to bend — its shape is nothing but the lengths of its members. So a truss's camber is a cutting list, and each millimetre on that list arrives at mid-span multiplied by the member's force under a unit load there: two and a half for the middle chords of a truss ten times as long as it is deep, nothing at all for some verticals. Build only the chords to their dead-load strain and a quarter of the sag stays, the webs' share. Cut every member to a millimetre of scatter and the mid-span misses by six, an eighth of the camber.

5 figures · Camber
The roller's pressure, not the soil's. Horizontal pressure down the back of a wall, for backfill of 20 kN/m³ and φ′ = 30° behind a wall 3.0 m high, compacted by a roller of 60 kN per metre of its width. Dashed, the soil's own active pressure, Kₐ·γz (Kₐ = 0.33), and at-rest pressure, K₀·γz (K₀ = 0.50). Solid, Ingold's compaction envelope: rising as the passive limit γz/Kₐ to 27.6 kPa at 0.46 m, then constant at √(2pγ/π) = 27.6 kPa all the way down, since the active pressure would not reach it until 4.15 m. Its thrust is 76.6 kN per metre of wall against the active 30.0, and its moment about the base 106.3 kN·m against 30.0. Equilibrium

The pressure the roller leaves behind

A retaining wall is designed for the pressure of the soil it holds, a triangle growing with depth. The soil behind most walls was not tipped there. It was placed in layers and rolled, and each pass of the roller pushed the soil sideways against the wall harder than the soil's own weight ever could, and left most of that push locked in when it moved on. Behind a 3 m wall compacted by an ordinary vibrating roller the locked-in pressure is a constant 28 kPa from half a metre down, the thrust two and a half times the active triangle's and the moment at the base three and a half.

5 figures · Lateral pressure
The force climbs back to the elastic one. The peak force of each of 40 drops of a 500 kg weight dropped 1.0 m onto a structure whose stiffness gives it 2.0 mm of static deflection under the weight, onto a structure yielding at 80 kN — half the 160 kN an elastic structure takes (dotted). Perfectly plastic, every drop peaks at 80 kN and the saving holds, at the price of the ratchet. Hardening at 2 per cent, the peak climbs drop by drop: 82 kN at the first, 91 at the fifth, 131 at the 40th; hardening at 5 per cent, the peak climbs drop by drop: 86 kN at the first, 104 at the fifth, 152 at the 40th. A hardening structure ends up carrying almost the elastic force it was made weaker to avoid. Dynamics

The same weight, dropped again

A structure allowed to yield under a falling weight needs only a fraction of the strength an elastic one needs — half of it for a ductility of two and a half — because the energy goes into bending the steel rather than into force. That is the whole saving, and it is spent on the first drop. Drop the same weight again and the structure yields again: a perfectly plastic one adds the same permanent set every time and never stops, and a hardening one stops only when it has stiffened itself back up to nearly the elastic force it was made weaker to avoid, after moving more than half a metre.

5 figures · Impact factor
Each fibre has to earn its own prestress. For each section on a 12 m span carrying its own weight and 20 kN/m more: bars, the top and bottom moduli it has; ticks, the moduli its two pairs of limits need — the top fibre holding the service compression and the transfer tension, the bottom holding the service tension and the transfer compression, both from the same prestress. The symmetric I: top 28.9 against 17.4 needed, bottom 28.9 against 23.5 (× 10⁶ mm³) — a prestress exists; the tee: top 48.5 against 17.8 needed, bottom 22.7 against 24.0 (× 10⁶ mm³) — no prestress exists; the bulb-tee: top 46.0 against 17.7 needed, bottom 37.4 against 23.8 (× 10⁶ mm³) — a prestress exists. Sections and stress

The flange the prestress cannot use

The four stress limits on a prestressed section pair up by fibre: the bottom fibre has to hold the service tension and the transfer compression from the same force, and the top fibre the service compression and the transfer tension. Each pair is possible only if that fibre's own section modulus is large enough, whatever the eccentricity. On a symmetric section the two pairs are close to balanced. On a tee they are not: its wide flange multiplies the top fibre's modulus and hardly touches the bottom's, so a tee with half as much concrete again as a symmetric I cannot be prestressed for a load the I carries.

6 figures · Prestress limits
The rib yields long before it would buckle. The largest combined stress, axial plus bending, anywhere in a 60 m two-pinned parabolic rib at a 12 m rise (EI 250,000 kN·m²) with a 12,000 mm² section 1,000 mm deep, against a factor on 15 kN/m of dead load over the span and 6 kN/m of live load over the left half together. Dashed: first order; solid: second order; dotted: the 355 N/mm² yield stress. First order, the rib reaches yield at a factor of 1.73; second order, at 1.18. The same load pattern, spread uniformly, would bifurcate the rib at a factor of 2.97, the right-hand edge — which is the number the eigenvalue reports and a number the rib never reaches. Stability

The weight that bends a rib it cannot bend

A parabolic rib carries its own uniform dead load as pure thrust, with no bending in it at all. Put a live load on half the span and the rib bends in the shape of its own buckling mode from the first kilonewton, and the whole thrust, most of it from the dead load, multiplies that bending. The rib never reaches its buckling load. It yields well short of it, at a load its first-order check says it can carry.

7 figures · Arch buckling
One quantity, three names. The middle braced bay's share of the storey force (solid) and one end bay's (dashed), for a 48 by 12 m plate, 200 mm of concrete, spanning two 24 m bays between three braced bays of 100,000 kN/m each, under 40 kN/m, against a factor on the plate's stiffness as built, on a logarithmic scale. The share moves continuously from 61 per cent, a continuous plate on unyielding supports, to 33 per cent, the rigid plate. Left of 0.02 (shaded) ASCE 7 calls the plate flexible and assigns tributary shares, 50 per cent to the middle; the plate there actually gives it 59 per cent at the boundary. Right of 1.54 (shaded) EN 1998-1 calls it rigid and assigns stiffness shares, 33 per cent; at that boundary the plate gives 37. The plate as built, factor 1, gives 38 per cent to the middle and 31 to each end. Structural form

Rigid by one code and not by the other

A floor plate between shear walls shares its storey force out in proportions that move continuously with its stiffness, from a continuous beam's to a rigid body's. The codes put it in one of two boxes and use a different model in each. ASCE 7 and EN 1998-1 draw their boxes' edges a hundred times apart in plate stiffness, each at a point where its own licensed model already misstates the middle wall by about a tenth — and an ordinary 200 mm slab sits in the gap between them.

6 figures · Diaphragm
Where each check bites. The c shape group with a 5.0 mm throat drawn to scale, loaded 1 mm from its vertical run. Offset from each weld, the use of each point: solid for the static directional check, dashed for fatigue at 2 × 10⁶ cycles, each scaled to its own worst point, which is marked. The static check's worst point is where the force runs most nearly along a weld; the fatigue check's is where it runs most nearly across one. Here the two checks are governed at different points, and a fatigue check made only at the static peak allows a load range 2.25 times the group's. Connections

Strongest across, and first to crack across

A fillet weld pulled across its length is √1.5 stronger than one pulled along it, and every static check of a weld group uses that. In fatigue the same two directions are rated the other way round: the part of the force across the weld is checked against a detail category of 36 and the part along it against 80. The point of a group that governs the static check need not govern the fatigue one, and checking fatigue there can allow more than twice the load range the weld will take.

7 figures · Weld group