Water pressure — where it appears
Named by 2 essays across one field — each of them below, with the objects they name alongside it.
The drain that fails a season at a time
A basement held at its design head by drains and a pump can fail suddenly, when the pump stops, or slowly, when fines settle in the drains and the head under the slab creeps up while the pump keeps running. The slow failure gives a standpipe read once a year a decade of warning, in its own time constants — if it is read in the wet season. And long before the silt floats the building on its own, it has made every stop of the pump more likely to.
The silt a jet cannot reach
A basement held down by drains that silt up floats in the spring of year 24 if nobody touches them. Clean them every four years and it floats in year 104 — if a fifth of the silting is in places no jet reaches; in year 44 if half is. The cleaning interval barely matters beside that share, and the share is not knowable when the drains are laid. But it is measurable as soon as they are first cleaned: the standpipe read just after a cleaning sees only the silt that stayed, and its trend is the drains' life.
Named alongside it
The objects these essays reach for when they reach for this one.
DrainageFlotationInspectionUpliftWater tableLimit stateServiceability