Weld strength — the series
-
The weld that is stronger across than along
The same fillet weld, the same size, the same steel, carries twenty-two per cent more when the load runs across it than along it. The factor is exactly the square root of three over the square root of two, and it comes out of the yield criterion rather than out of a test.
-
The weld that is stronger where it is pulled
A fillet weld pulled across its axis is √1.5 stronger than the same weld pulled along it. On a group under an eccentric load the direction of the pull varies from point to point, so the capacity does too — and the gain that follows is worth twenty per cent at one eccentricity and nothing at all at another.
-
The throat that misses the load
A partial-penetration butt weld's throat faces the load squarely, so a millimetre of it carries more than a fillet's, and in every grade what limits it is a cap on normal stress rather than the directional criterion. Made from one side, the throat sits off the plates' line of action. At half penetration it keeps a quarter of that capacity, and the stress the eccentricity adds lands on the root, which is a crack.
-
The shear that helps a butt weld
A partial-penetration butt throat pulled straight across its weld is capped at 0.9fu, which in S355 makes it 15 per cent stronger than a fillet throat. Add a little shear along the weld and the butt throat gets stronger, not weaker, because the cap limits only the normal stress — until the shear is 42 per cent of the pull, where it is 29 per cent stronger than the fillet and carries its largest resultant, 478 N/mm² against 441 straight across. Along a moment connection's web weld the mix of pull and shear sweeps through that peak, and in the direction that is all shear a single-sided throat is as good as two.