Weld group — the series
-
The corner that is not the worst point
Check the point furthest from the centroid. It is the standard rule for a weld group under an eccentric load, it is exactly right for some shapes, and for others it misses the peak by sixteen per cent — or picks one of four points it cannot tell apart whose stresses differ by two thirds.
-
The radius rule, and where it fails
A weld group under an eccentric load is checked at the point furthest from its centroid, on the reasoning that the stress from the twist grows with the radius. That reasoning ignores the direction the two stresses point in, and for one common shape it misses the peak by nine per cent.
-
The eccentricity at right angles to the drawing
A bracket's load stands off the plane of its welds as well as being offset within it, and the second eccentricity produces a completely different object — bending about an axis through the group rather than torsion about a point in it. The weld line has no compression zone to argue about, so its neutral axis is its own centroid, and the whole length works.
-
Two fasteners that never arrive together
Every steel code forbids adding a weld's capacity to a bolt's in one shear joint, and states it as a rule rather than deriving it. It is derivable. Two fasteners in parallel are at the same displacement rather than the same force, and a weld has ruptured at four tenths of a millimetre while a bolt in a standard hole has not yet touched the side of it.
-
Strongest across, and first to crack across
A fillet weld pulled across its length is √1.5 stronger than one pulled along it, and every static check of a weld group uses that. In fatigue the same two directions are rated the other way round: the part of the force across the weld is checked against a detail category of 36 and the part along it against 80. The point of a group that governs the static check need not govern the fatigue one, and checking fatigue there can allow more than twice the load range the weld will take.
-
A quarter of the weld takes half the pull
A beam flange welded straight on to an unstiffened column flange is checked with an effective width of 191 mm out of 250. While the joint is elastic the plate's force does not use anything like that width: 47 per cent of it goes through the 65 mm over the web, and the flange has already yielded at 30 per cent of the force the rule allows. The rule's width is a plastic width, and the full-strength weld it insists on is what lets the joint get there.