Ladder

Storey buckling — the ladder

One essay so far against this idea. A ladder is the distinct arguments that stand against one idea, and this one has room to grow.
  1. Effective length is a property of the storey. The effective length factor of the one column that resists sway, against the total gravity load on the storey as a multiple of its own. At the left-hand end it carries the storey alone and its K is 1.99 — the 2.0 every chart gives a column fixed at the base and free to sway at the top, reproduced here by a route that never mentions a chart. Then columns are added that have pinned bases and therefore no lateral stiffness whatever. They contribute load and nothing else, so they cannot buckle on their own and they lower the load at which everything buckles together. K rises as the square root of the load ratio, exactly, and at the storey drawn — three leaning columns carrying 69% of the gravity load — it is 3.57. That is off the end of every published alignment chart, and the leaning columns themselves, which a designer would take at K = 1.0 for pinned ends, are at 2.54.

    The column that leans on its neighbours

    A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.

    rung 1 · stability

All ladders