Series

Snap-through — the series

6 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. A load with a maximum in it, and nothing bifurcates. Load against apex movement for a two-bar frame of half-span 1000 mm and rise 150 mm. The load rises to 133.4 kN at a movement of 64 mm — well short of the 150 mm that would bring the apex level — and then falls. Past that point the frame can only be held by taking load away, so under a dead weight it goes: 260 mm of movement at constant load, arriving inverted and in tension. The minimum on the path is -133.4 kN, the exact negative of the maximum, because the geometry is symmetric about the flat position and the arithmetic knows it.

    The roof that jumps

    Every stability failure in this collection so far has been a bifurcation — a straight thing discovering it can be bent. A shallow frame does something else entirely. It stays perfectly symmetric, deforms steadily, and at some point the load it can carry starts to fall while it is still moving in the direction it was pushed.

    part 1 · stability
  2. The arch turns aside before it reaches the top of its path. The load parameter p = 16qL⁴/π⁴EIr against the crown's deflection, in radii of gyration, for a shallow pinned arch whose rise is 6.0 times its radius of gyration. Kept symmetric (dashed) it would carry the load to a limit point at p = 374.7. It never gets there: at p = 310.7 a sideways path branches off (solid), along which the load falls as the arch sways — the failure is a bifurcation, 17 per cent below the limit point. With an antisymmetric imperfection of 0.10 radii of gyration (thin line) the arch follows neither path and peaks at p = 272.6, 12 per cent below the perfect arch.

    The arch that turns aside before it snaps

    A shallow frame of pinned bars can only go one way when it is pressed: down, symmetrically, over a maximum. An arch that bends has a second way out — sideways, one half dropping while the other lifts — and above a rise of about four and a half radii of gyration it takes that way before it ever reaches the maximum. The switch decides more than the load. Below it an arch is almost indifferent to a sideways imperfection; above it the load an arch carries falls as the two-thirds power of how crooked it was built, and a tenth of a radius of gyration costs it an eighth of its strength.

    part 2 · stability
  3. A brace on the sideways mode gives back the snap. The load parameter against the crown's deflection, both in radii of gyration, for a shallow pinned arch whose rise is 8.0 radii of gyration, built 0.1 of a radius of gyration out of shape in its sideways mode, unbraced and with a brace on the sideways mode of 0.88, 1.75, 3.50 times the rib's own antisymmetric bending stiffness. Unbraced it peaks at 410; with 0.88 it peaks at 658; with 1.75 it peaks at 794; with 3.50 it peaks at 840. The perfect arch's limit point, which a brace can only return it to, is 844; unbraced, it turns sideways at 461.

    The brace that holds a mode

    A shallow arch rising eight radii of gyration turns sideways at a load of 461 when its symmetric snap would not come until 844. A member that only stops the quarter points moving in opposite senses — a brace on the sideways mode, not on any one point — gives the whole difference back once it is 1.75 times as stiff as the rib's own resistance to that mode, and nothing more after that. The stiffness needed grows as the square of the rise. And the brace is not the light member the argument suggests: an arch built a tenth of a radius of gyration out of shape puts an eighth of its whole load through it at the peak.

    part 3 · stability
  4. A stiff enough crown brace stops the arch snapping. The load parameter against the crown's deflection for a shallow pinned arch of rise 6.0 radii of gyration under a sinusoidal load, built with an antisymmetric imperfection of 0.10 radii of gyration, with a crown brace of κc = 0, 1, 2, 4; the dots mark the first peak of the load, where the arch snaps. κc = 0: peaks at 273; κc = 1: peaks at 299; κc = 2: peaks at 327; κc = 4: no peak, the load rising throughout.

    The prop at the crown of the arch

    A shallow arch that turns sideways before it snaps can be braced at its quarter points, which holds the sideways mode and carries almost nothing. A single prop at the crown is cheaper and does something else. The crown does not move in the sideways mode, so the prop cannot stop it; it raises the load at which the arch turns aside only by taking part of the load itself. But behind a prop about three times as stiff as the rib's own first mode, the sideways branch stops falling, and the arch no longer snaps at all — at every rise, by the same prop.

    part 4 · stability
  5. A concrete rib creeps into snapping long before its prop matters. For the shallow pinned arch of rise 6.0 radii of gyration under a sinusoidal load, propped at its crown by a concrete column of stiffness κc = 3.5, the creep coefficient at which a load that stays on loses equilibrium, against that load as a share of the day's critical load: a steel rib on the creeping column (solid), which loses only the column's share, so that by a creep coefficient of 3 no load below 85 per cent snaps; and a concrete rib whose column creeps with it (dashed), whose lasting load acts as if (1 + φ) times larger, so that it snaps at φ = pcr/p − 1; dotted, a creep coefficient of 2. At half the critical load the concrete arch snaps at a creep coefficient of 1.00, at 70 per cent at 0.43; the steel arch on its column does not snap at either.

    The column that creeps under the arch

    A shallow arch propped at its crown by a stiff enough column stops snapping — the sideways branch it would have fallen down turns upwards. If the column is concrete, it creeps under the force it holds, and after a decade it holds that force as a spring a third as stiff, well on the side where the arch snaps. But a load that arrives in seconds does not meet the crept column; it meets the column's instantaneous stiffness, from a rest length that creep has merely moved down, and the arch's branch still rises. Creep reaches only the load that stays on, and there it can take back only the column's own share — 13 per cent of it. A concrete rib is another matter: it creeps itself, and a lasting load at half its critical load snaps it before its creep coefficient reaches one.

    part 5 · stability
  6. The arch hung at its crown, and hung from anchorages that have slipped. A shallow arch of rise 6.0 radii of gyration: load against the crown's deflection, along the symmetric path, unhung and hung from a strand of 3.5 times the rib's own first-mode stiffness. Hung, it turns sideways at 390 and its sideways branch rises; unhung, at 311, and the branch falls. A slip of 0.9 radii of gyration leaves the hanger slack until the crown has come down that far, and the arch turns aside at 343, still braced; a slip of 1.8 is never taken up, and the arch snaps at 311.

    The hanger that loses force and keeps its stiffness

    A concrete column propping a shallow arch's crown creeps, and the stiffness it offers a lasting load falls with it, until the arch can snap under a load it carried on the day. A steel strand hanging the crown from above does not creep. It relaxes, losing force at constant length, and its anchorage may slip. Both turn out to cost the arch almost nothing — and the slip, which is a gap rather than a spring, costs nothing at all until it is as large as the crown's whole deflection at buckling, when it costs everything.

    part 6 · stability

All series