Series

Shear deflection — the series

4 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The shear part is not a curve at all. A 300 × 600 rectangle spanning 2,400 mm, a span-to-depth ratio of 4, with its bending deflection and its total drawn together. Bending gives 0.0254 mm and shear a further 0.0049 mm, so 16.3% of the movement is the term beam theory drops. The shear part is drawn separately beneath: two straight lines meeting under the load, each limb straight to 2e-16 of the peak. It is the shear diagram integrated once where the moment diagram above it is integrated twice, so it carries one degree of curvature less than the bending shape — none at all here. The real movement is 1 in 79,116 of the span; both panels are drawn at about 11,932 times it.

    The deflection that is not bending

    Engineer's beam theory computes a deflection as the second integral of a moment, and that calculation silently drops a term. The beam also shears, and the shear deflection is not a correction to the curve — it is a different shape, and for a deep member it is most of the answer.

    part 1 · deflection
  2. The shear deflection is not a correction. The share of a sandwich panel's deflection that is shear rather than bending, against how slender the panel is. A solid beam at a span-to-depth ratio of 20 spends about a per cent of its deflection on shear; this panel spends 25% at the same ratio, because its core is 2800 times softer in shear than its faces are in tension. At the 37 of the panel drawn it is 9%. The curve falls as the square of the span because bending grows as the fourth power and shear as the second, so the term that is negligible for a long panel is the whole answer for a short one.

    The stiffness that belongs to the span

    A section's flexural rigidity is a property of the section, and a member's is not. Once shear deformation is counted the effective stiffness contains the span, so the same panel is a different member at three metres and at six — and for a sandwich the correction is not a correction.

    part 2 · deflection
  3. Soft in shear, the wall gives up moment to the span. The bending moment along a 300 × 600 rectangle fixed at its left end and propped at its right, under a uniform load, per unit load and span, at span-to-depth ratios of 4, 2, 1, and for the same beam treated as rigid in shear, dashed. Rigid in shear the wall carries 0.125 wL² and the prop 0.375 of the load. Counting the shear it deforms by, the wall moment falls to 0.119 wL² at 4, 0.105 wL² at 2, 0.070 wL² at 1, and the prop's share rises to 0.381, 0.395, 0.430. The load has not changed and the beam is no weaker: its forces have moved, because in a redundant beam they come from how it deforms.

    The shear that moves the moments

    In a statically determinate beam, shear deformation adds movement and changes no force. In a redundant one the forces come from how the beam deforms, so a stubby beam soft in shear carries less moment at its wall and more in its span — and the carry-over factor, the one half every hand method passes along, falls to nothing at φ = 2 and then changes sign.

    part 3 · deflection
  4. The shear term cuts the beam's stiffness, not its share. For 20 storeys of two 6.0 m walls 0.35 m thick either side of a 2.4 m opening, coupling beams 0.35 m wide, 60 kN at every floor, against the coupling beams' depth: each beam's stiffness with its shear deformation counted over its stiffness in bending alone, the degree of coupling likewise, and the largest beam's shear likewise. At a depth of 0.6 m (span over depth 4.0) the stiffness is 0.85 of the bending figure, the coupling 0.977 and the shear 0.961; at 2 m (1.2), 0.33, 0.973 and 0.937. Where the shear term is large the beam is stiff enough that its stiffness has stopped deciding anything.

    The coupling beam asked for shear

    The coupling beams of a pair of shear walls are the stubbiest members in a building, and the shear term in their deflection is largest exactly there: a beam two metres deep over a 2.4 m opening is a third as stiff as bending alone says. The walls hardly notice. The pair's degree of coupling moves by under 3%, the beams' shears by under 7%, because a beam that stiff has stopped deciding how much of the overturning the walls carry as a couple. What decides it is the shear the beams can give. A 600 mm beam limited to 2 N/mm² starts to yield at 1.9 times the storey force; past the last yield the pair is two cantilevers again, and the beams supply rotation instead.

    part 4 · deflection

All series