Robustness — the series
-
The structure that survives losing a member
Every check in this collection asks what a structure carries. None of them asks what is left when part of it is gone — and two frames with the same members, the same weight and the same factor of safety can answer that question completely differently.
-
A determinate truss has no robustness at all
Remove any one of a Warren truss's thirty-one members and what is left is a mechanism. Not weakened — gone, with no set of forces that holds the load in any position. Robustness is not a property a structure has by degree; it is bought by adding members that carry nothing until something else stops carrying, and a truss without them has none of it to measure.
-
The factor of two belongs to one mode
A member that fails suddenly hands its force to the structure around it all at once, and the convention is to double the static answer: a load applied suddenly to a spring overshoots to twice its static deflection. A truss is not one spring. Take a diagonal out of a counter-braced truss in an instant and some members swing to three times their change of force, one swings the wrong way first, and a bottom chord whose force does not change at all passes through half as much again as it carries — because every mode overshoots by two, at its own time, and a member is a sum of modes.
-
The cable that pays the factor back
A frame that loses a column carries the floor across the gap first by bending and then, as the beam sags, as a cable. The hope is that a path which stiffens as it deflects needs less than the factor of two a suddenly loaded spring does. On the bending plateau it does — 1.18 at nine tenths of the collapse load. But past one depth of sag the cable is a straight line again, and the factor climbs straight back toward two: 1.73 at one and a half times the collapse load. And the connections are asked for a tenth of a radian on the way.
-
The slab that catches what the joints let go
When an interior column is lost, the beams that crossed over it sag into cables and the slab over the four bays round it sags with them, into a membrane hanging from the floor that did not lose anything. Whether the floor's robustness belongs to its steelwork or to its concrete turns on one number with no span in it: the slab's mesh only starts to carry its full tension when the beams' ends have turned through about 0.09 radians, more than any ordinary joint can follow. So the membrane arrives after the joints have gone. And then it catches the floor — a metre down, alone — and with an ordinary mesh it holds half as much again as the beams could.