Ladder

Pile group — the ladder

One essay so far against this idea. A ladder is the distinct arguments that stand against one idea, and this one has room to grow.
  1. The group is not weaker; it is very much softer. A 3 × 3 pile cap on the left, with each pile's share of 9.0 MN and 4.5 MNm in meganewtons — N/n plus M·y/Σy², the same three terms in the same order as a bolt group under an eccentric load and a section under biaxial bending. The corner piles take 1.25 times the average and a pile added at the centroid would change that by nothing at all, because it adds to neither second moment. On the right is the effect a bolt group cannot have: the piles share ground, so the stress bulbs overlap and the group settles 3.9 times as much as a single pile at the same load per pile, rising to 14.2 for 144 of them. The capacity check everyone makes — block failure against the sum of the piles — comes out at 4.54 here and does not govern at all. The check nobody tabulates is the one that does.

    Nine piles, and four times the settlement

    A pile cap divides its load between its piles by the same three terms a bolt group uses and a section under biaxial bending uses. What a bolt group does not have is neighbours it shares ground with — and the group effect that matters is not the strength check everybody makes, but a stiffness effect nobody tabulates.

    rung 1 · structures

All ladders