Series

Membrane action — the series

2 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The same restraint, twice, with opposite signs. A 4 m strip of 200 mm slab whose ends cannot move apart, against deflection measured in its own thicknesses. The flat line is what a yield-line calculation gives, which is what the same strip would carry if its ends were free: 30.0 per unit width. The rising branch is compressive membrane action — the deflected strip is forced into an arch — and it peaks at 116.6, which is 3.89 times the yield-line load, at a deflection of 0.24 of the thickness. Past that the arch runs out of depth and the load falls back to the flexural one; past a deflection of one thickness there is no arch left and the reinforcement starts carrying the strip as a cable. It gets back to the arch's load at 2.17 thicknesses, which is one part in 9 of the span — a sag nobody would design for and exactly what a floor does instead of falling.

    The force nobody put in the model

    A slab strip whose ends cannot move apart is not the strip in the yield-line calculation. Deflecting shortens the chord between its ends, the ends do not come in, and the strip is forced into an arch — worth four times the load it was designed for, at a movement nobody would see.

    part 1 · internal-forces
  2. The arch is only as strong as what holds its ends. Load against mid-span deflection, as a share of the thickness, for a slab strip 4,000 mm long and 200 mm thick, a metre wide, with its ends held by springs of 0.05, 0.5 and 5 times its own axial stiffness EA/L and rigidly; dashed is its flexural load, 30.0 kN/m. At 0.05 EA/L it peaks at 45.3 kN/m, 1.51 times the flexural load, at 0.67 of its thickness; at 0.50 EA/L it peaks at 74.8 kN/m, 2.49 times the flexural load, at 0.45 of its thickness; at 5.00 EA/L it peaks at 108.6 kN/m, 3.62 times the flexural load, at 0.28 of its thickness; held rigidly it peaks at 116.8 kN/m, 3.89 times the flexural load, at 0.24 of its thickness. A soft restraint lets the ends move out as the strip tries to arch, so the thrust builds slowly and the peak arrives later and lower.

    The edge that cannot hold the arch

    A slab strip whose ends cannot move apart arches inside its own depth and carries nearly four times its flexural load. "Cannot move apart" is a stiffness, not a fact, and the arch needs a lot of it: half the gain takes end springs about half as stiff as the strip itself in compression, and nine tenths takes springs five times as stiff. An interior panel is held by the floor around it and gets the arch. An edge panel is held on its outer side by whatever runs along the edge, and a band of slab two metres wide between columns eight metres apart supplies a twentieth of what the strip needs. The arch is a property of where the panel is.

    part 2 · internal-forces

All series