Series

Framed tube — the series

One essay so far on this idea, and more questions about it than one essay answers.
  1. The corner columns take what the middle ones did not. Axial stress in the columns across one flange face of a 30 by 40 m framed tube, at the base. Plane sections says the flat line: every column on the face at the same distance from the neutral axis, therefore at the same stress. The solved distribution is the curve — 69.4 N/mm² at the corner against 18.2 in the middle, a ratio of 3.81. The middle columns lag because the only route the axial force has into them is the in-plane shear of the spandrel frame, bay by bay from the corner. The face is carrying its resultant on an effective width of 51 per cent, and the tube deflects as though its second moment were 72 per cent of the gross.

    The corner columns take more than their share

    A framed tube is a hollow cantilever, and a hollow cantilever's flange ought to be uniformly stressed. It is not, and the reason is that the only route the axial force has into a column in the middle of a face is the in-plane shear of the frame — one bay at a time, from the corner inwards.

    part 1 · structures

All series