One essay so far against this idea. A ladder is the distinct arguments that stand against one idea, and this one has room to grow.
  1. A transverse load with nothing applied. Web slenderness against web thickness, with the limit the flange's own curvature sets. A flange carrying 6213 kN and curved to a radius of 592 m needs 10.5 N per millimetre of radial force to stay on its curve, and the only thing available to supply it is the web. Nothing has been applied to the girder: the load comes from the deflected shape, which is why a straight beam has none of it and a beam at a plastic hinge has a great deal. Setting the radial force against the web's own plate-buckling resistance gives, in four lines, h_w/t_w ≤ k·(E/f_yf)·√(A_w/A_fc) — the form the codes use, arrived at without them. The constants differ: an elastic flange strain gives k = 1.34 and the rule uses 0.3, a factor of 4.5, and the gap is the curvature assumed. k goes as the inverse square root of the flange strain, so 0.3 is a flange strained to 3.4% — which is what a plastic hinge does to it. The rule is not conservative; it is written about a different beam.

    The web that is crushed from inside

    A plate girder's compression flange is curved by the beam's own deflection, and a curved force needs a transverse load to stay on its curve. The only thing available to supply it is the web. So a deep girder can buckle its web vertically with nothing applied to it at all, and the rule that prevents it is the only clause in the codes about a load no load case contains.

    rung 1 · stability