Series

Elastic foundation — the series

5 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. The ground pushes back hardest where the beam has gone down furthest. A strip 16.4 m long and 1 m wide on ground of subgrade modulus 50 × 10³ kN/m³, carrying 1000 kN at its centre. The beam settles 3.90 mm under the load and the ground pushes back in proportion — the arrows are k times the settlement above them, peaking at 195 kN per metre — so the pressure diagram is the settlement bowl and not an assumed distribution. The characteristic length 1/β is 2.56 m: the bowl crosses zero at 6.04 m, which is 3π/4 of it, and beyond that the arrows reverse because the beam has lifted off. By 8.05 m — one π/β — the disturbance is 4.3% of what it was, which is why the moment 641 kNm and the peak pressure 195 kN/m contain no length at all. The settlement is drawn 217 times full size — the real bowl is 3.90 mm deep over 16.4 m, about 1 in 4207 — and at true scale the beam would be a straight line.

    The beam that sits on the ground

    Every other beam in this collection is held at points. A footing is held everywhere, by something that pushes back in proportion to how far it is pushed — and that single change hands the structure a length it did not choose. Two or three of those lengths from the column, nothing knows the load happened.

    part 1 · internal-forces
  2. The linear answer has the ground holding the ends down. The contact pressure along a strip 16 m long, EI 5.40 × 10⁵ kN·m², on a bed of 50 × 10³ kN/m² per metre of its length, under a column of 1,000 kN. With springs that pull as readily as they push (dashed) the bed presses 197 kN/m under the column and pulls down on the ends at up to 34 kN/m — tension the ground cannot supply. With the pulling springs released (solid), the strip touches the ground only from 3.97 m to 12.03 m, 8.05 m in all, and presses 213 kN/m under the column, 8 per cent more; beyond that it carries nothing.

    The ends the ground was holding down

    Winkler's springs pull as readily as they push, and on a long footing strip the linear answer quietly uses that: it has the ground holding the strip's ends down. Take the pull away and the correction under the column is modest — eight or nine per cent on the pressure and the moment — but the shape of the answer changes completely. A weightless strip longer than about eight metres keeps exactly eight metres of itself on the ground, whatever length was poured, and the rest rises off as straight cantilevers carrying nothing. The middle-third rule turns out to be a property of rigid footings: an eight-metre strip lifts at a fiftieth of the eccentricity the kern allows.

    part 2 · internal-forces
  3. Ground already loaded rocks stiffer than springs that are not. The moment on the column against its rotation through a storm that takes the moment to ±1,000 kN·m and back, for an 8 m strip of EI 540 MN·m² on a bed of 50 MN/m² under a 1,000 kN column: on elastic springs that cannot pull, and on ground that unloads and reloads 4 times as stiffly as it first loads, in the first storm and the third. On elastic springs the column turns 1.418 milliradians at the peak, a rocking stiffness of 0.70 GN·m/rad, the same every storm. On the remembering ground it turns 1.116 in the first storm and 0.868 in the third — 0.90 and 1.15 GN·m/rad — because rocking unloads half the strip, and ground that has carried the column unloads stiffly.

    The footing the storms press down

    A footing strip under a column that a storm rocks one way and then the other was expected to dig itself a bowl: its ends loaded half the time, compacted, and left hanging over the hollow. On ground that unloads and reloads four times as stiffly as it first loads, the bowl appears and the strip fills it. The column settles 26% more over three storms and then stops; the footing rocks 22% less than it did in its first storm and is 64% stiffer than on springs that forget, because rocking unloads half the strip and ground that has carried the column unloads stiffly. The storms change the settlement and the stiffness, and leave the moments almost where they were.

    part 3 · internal-forces
  4. A prevailing wind leans the footing, and the lean stops. The 8 m strip of EI 540 MN·m² on a bed of 50 MN/m² under a 1,000 kN column on ground that unloads and reloads 4 times as stiffly as it first loads, rocked by storms that push to 1,000 kN·m one way and swing back all, three quarters, half, a quarter or none of that the other: the column's tilt at rest after each of eight storms, in milliradians, positive the way the storms push. After eight: 0.011, 0.064, 0.117, 0.171, 0.218. Each settles within three storms; the lean is set by how unequal the storms are, not by how many there have been.

    The footing a prevailing wind leans

    A footing rocked by storms that reverse evenly settles into a symmetric bowl and stops. A footing under a frame in a prevailing wind is pushed harder one way than the other, and its ground keeps the difference. It leans — and then it stops leaning, within three storms, at a tilt set by how unequal the storms are and how large the largest has been. Fifty years of storms lean it further only in the years when a storm beats every one before it, and between those years nothing that happens to the footing moves it at all.

    part 4 · internal-forces
  5. Pressed and pulled, the footing leans once and stops. The column's tilt at rest after each of eight storms reversing fully to 300 kN·m each way, on the 8 m strip of EI 540 MN·m², weighing 320 kN, on a bed of 50 MN/m² under a column carrying 1,000 kN, on ground that unloads and reloads 4 times as stiffly as it first loads, for loads swinging by 0, 50, 100, 150, 200 per cent. 0 per cent: −0.007 milliradians after the first storm and 0.003 after the eighth; 50 per cent: 0.112 milliradians after the first storm and 0.103 after the eighth; 100 per cent: 0.109 milliradians after the first storm and 0.091 after the eighth; 150 per cent: 0.113 milliradians after the first storm and 0.095 after the eighth; 200 per cent: 0.114 milliradians after the first storm and 0.102 after the eighth. The lean is towards the end the heavier half of each storm presses; it stops within three storms whether or not the strip ever hangs clear.

    The footing that hangs from its column

    A footing under a bracing bay's column is pressed hard when the wind pushes one way and pulled when it swings back, and if the pull is larger than the footing's weight it hangs from the column, clear of the ground, for part of every storm. It looks like a footing free to come down somewhere new each time, and walk. It does not walk. The ground under it keeps the memory of every press, and a footing that is not touching the ground cannot change that memory; it comes back down into its own bowl, leans once towards its harder press, and stops within three storms.

    part 5 · internal-forces

All series