Series

Cable-stayed — the series

One essay so far on this idea, and more questions about it than one essay answers.
  1. A fan, and where its forces go. Half a cable-stayed bridge: a tower 70 m above a deck, 12 stays reaching out over 200 m, and a uniform 200 kN/m on the deck. Each stay is drawn at a weight proportional to the force in it, from 3427 kN at the innermost to 10090 kN at the outermost — the outer stay carries the same vertical share and is far flatter, so it carries far more. The deck's shading is its own accumulated compression, 61905 kN at the tower, which is 1.55 times the load being lifted and is the horizontal half of every stay force added up. Nothing in this drawing is a catenary: every stay is straight and every one of them is a spring.

    The cable that is a spring

    A suspension bridge's cable is a funicular — it takes the shape the load gives it, and the deck's job is to make the load one that shape is right for. A stayed deck is not that at all. Its cables are straight, each reaches the deck at one point, and every one of them behaves as an inclined spring.