Series

Branching structure — the series

One essay so far on this idea, and more questions about it than one essay answers.
  1. The split is where buckling puts it. A branching column carrying 400 kN to two points 3.0 m apart, over 9.0 m. Every member is drawn at the thickness it needs: the area is the larger of N/σ and what Euler asks of a strut of that length, and 3 of 3 members here are sized by buckling rather than by strength. The split sits at 57% of the height, which is where the total volume is least — 51% less than the fan of straight struts that carries the same load with the same stresses.

    The tree that strength does not ask for

    A branching column carries a roof on many points and reaches the ground on one. Size every member by its stress and the optimum tree turns out to have no trunk at all — the best answer is a fan of straight struts from the base. Put buckling in and the trunk appears, at 57 per cent of the height.

    part 1 · structures

All series