Series

Bearing — the series

2 essays on one idea, from the one that introduces it to the one that assumes the rest.
  1. Bearing and tear-out against end distance. A 20 mm bolt in a 10 mm plate. Below 165 mm of end distance the bolt tears a channel out to the end and the capacity is proportional to that distance; above it the plate crushes in front of the bolt and the end distance stops mattering. At 40 mm the capacity is 52.12 kN and the mode is tear-out.

    The hole that goes oval, and the one that tears to the edge

    A bolt pressing on the side of its hole either crushes the plate in front of it or shoves a channel of metal out to the end. Which one happens is decided entirely by a distance that is usually set by a minimum in a table.

    part 1 · connections
  2. The group's load against the plates' travel, fitted and misaligned. The force on eight bolts in holes misaligned within ±2.0 mm, against the same bolts fitted, as the plates travel. The misaligned group needs 3.9 mm to reach half its nominal strength where the fitted one needs 0.9, and it peaks at 95% of nominal against 98%, at 8.6 mm, as its first bolt fails.

    The bolts that arrive one at a time

    A bearing bolt sits in a hole two millimetres bigger than itself, so a group of them is not in contact until the plates have moved, and each bolt reaches its hole at a different moment. Every calculation then shares the load equally. That is nearly right at failure and wrong on the way there, and what repairs it is a property nobody writes on the drawing: how far a bolt can travel before it breaks.

    part 2 · connections

All series