Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
Which limit arrives firstUtilisation of the strength limit and of the deflection limit, against span. Strength grows as the square of the span and deflection as the fourth power, so the two cross — and past the crossing a beam is sized by how far it moves rather than by what it can carry.0.60.811.21.41.61.8200.511.5span, relative to the firstthey cross heredeflection runs out at 1.40strength runs out at 1.54the limitstrengthdeflection

5 essays call which-governs. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

0.60.811.21.41.61.8200.511.5span, relative to the firstthey cross heredeflection runs out at 1.40strength runs out at 1.54the limitstrengthdeflection Deflection

Stiffness is not strength, and usually it is the one that governs

A beam can be nowhere near failure and still be unusable, because it has moved too far. For most long-span members that limit arrives first, and stronger steel does not help at all.

11.522.533.54050100150200250300span, relative to the first16×81×256×moment: the squareload: the first powerdeflection: the fourth Deflection

Span to the fourth, which is why spans are short

Doubling a span multiplies its deflection by sixteen. No other relationship in ordinary structural work is that steep, and it is the reason long spans are always a different kind of structure.

simply supportedstatics alonesag 32.0propped at one endneeds stiffnesssag 18.0hog 32.0built in at both endsneeds stiffnesssag 10.7hog 21.3the load never changes; only what is holding the endsthe built-in case peaks at two-thirds of the simple span's moment Deflection

One support too many, and what it costs to know

Add a redundant restraint and the load has two routes to the ground. Equilibrium cannot say how it splits, and the answer turns out to depend on stiffness — which is a different kind of question.

this support 0.01 lowmoment19.6 sagging24.5 hogging30.6 if the spans were simplereactions 14.0 38.5 38.5 14.0 — the inner supports carry far more than a sharethe continuous case needed stiffness; the comparison did not Deflection

The support that moved

A redundant structure knows things statics cannot see. Settle one support by ten millimetres and a complete set of bending moments appears — in equilibrium with no load at all, and larger for a stiffer beam.

00.020.040.060.080.10.120.1400.20.40.60.81sag at the middle of the baywater depth ÷ critical depthλ = 1.00, approached and never reachedreversed construction camber: δ₀ = 0.01 Deflection

The water that will not run off

A flat roof deflects, the deflection makes room for water, the water deepens the deflection. It is the same equation as a buckling column, with rain in place of the axial load.