Generator

The span-fourth generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
Deflection goes as the fourth power of the spanDeflection against span for a constant load intensity and section, with two slower relationships drawn faintly behind it for comparison: the load itself, which grows in proportion to the span, and the bending moment, which grows as its square. Doubling the span multiplies the deflection by sixteen, while the moment only quadruples.11.522.533.54050100150200250300span, relative to the first16×81×256×moment: the squareload: the first powerdeflection: the fourth

4 essays call span-fourth. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

neutral axiscontribution of each striptotal I = 79.86 × 10⁶the outer strips do almost all of the work Sections and stress

The material far from the middle does nearly all the work

A strip of steel contributes to bending stiffness in proportion to the square of its distance from the centre. Move the same steel outward and the section gets stiffer for nothing.

0.60.811.21.41.61.8200.511.5span, relative to the firstthey cross heredeflection runs out at 1.40strength runs out at 1.54the limitstrengthdeflection Deflection

Stiffness is not strength, and usually it is the one that governs

A beam can be nowhere near failure and still be unusable, because it has moved too far. For most long-span members that limit arrives first, and stronger steel does not help at all.

11.522.533.54050100150200250300span, relative to the first16×81×256×moment: the squareload: the first powerdeflection: the fourth Deflection

Span to the fourth, which is why spans are short

Doubling a span multiplies its deflection by sixteen. No other relationship in ordinary structural work is that steep, and it is the reason long spans are always a different kind of structure.

00.020.040.060.080.10.120.1400.20.40.60.81sag at the middle of the baywater depth ÷ critical depthλ = 1.00, approached and never reachedreversed construction camber: δ₀ = 0.01 Deflection

The water that will not run off

A flat roof deflects, the deflection makes room for water, the water deepens the deflection. It is the same equation as a buckling column, with rain in place of the axial load.