Two faces, a couple, and a core that does none of it
Two faces, a couple, and a core that does none of it. A sandwich section 61.4 mm deep: two 0.7 mm faces separated by 60 mm of core. The bending is carried as a couple between the faces — 41 N/mm² of tension in one and compression in the other, over a lever arm of 60.7 mm — and the core carries a shear stress of 0.047 N/mm² and nothing else. The parallel-axis term is 98.8% of the section's second moment; the faces' own bending about their own centroids is 0.004% of it, and the core's is 1.2%. Separated by nothing at all the same two faces would be 2.3e+4 times less stiff.
3 essays call
sandwich. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever
member of the family the generator happens to default to rather than the one its essay
argues about.
Where it is called
Changing this generator changes every one of these figures.
Two skins and the space between them
A sandwich panel is a section made of a material that carries the bending and a material that carries none of it. The parallel-axis term is not a correction here — it is 98.8 per cent of the second moment — and the shear deflection is not a correction either.
The stiffness that belongs to the span
A section's flexural rigidity is a property of the section, and a member's is not. Once shear deformation is counted the effective stiffness contains the span, so the same panel is a different member at three metres and at six — and for a sandwich the correction is not a correction.
The face that dents and the core that crushes
A sandwich panel carries bending as a couple between its faces, and that is a calculation about the whole panel. Put a local load on one face — a foot, a fixing, a dropped tool — and the face becomes a thin beam on a soft bed, spreading the load over a length the fourth root of their stiffnesses sets. Then either the face yields and dents, or the core crushes beneath it, and which comes first is decided by one thickness: below it the face gives, above it the core does, and a steel-faced roof panel is on the wrong side of it for anyone who walks on it.