Generator

The middle third, computed

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
The middle third, computed. The kern of a 400 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±66.7 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows.

The middle third, computed. The kern of a 400 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±66.7 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows.

8 essays call kern-zone. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

Weight is the only thing holding it down. A body 2.5 m wide and 6 m tall weighing 120 kN, under a wind pressure of 1 kN/m². The wind delivers 48 kN and an overturning moment of 144 kNm about the leeward toe; the weight restores 150 kNm, a factor of 1.04. The resultant lands 1.20 m from the centre against a middle third of ±0.42 m, so the base is lifting over 2.35 m of its width. Equilibrium

Weight is the only thing resisting it

A structure that is strong enough everywhere can still be blown over, and nothing in its material properties has any part in whether it is. The whole answer is a weight and a width — and the failure begins long before anything tips, at the moment one edge stops pressing down.

Two triangles that cross zero, and a block that does not. Stress across a 300 × 700 mm section at each stage, compression positive. The prestress alone gives -6.33 MPa at the top and 20.61 at the bottom; at transfer, with only self-weight on it, the top is at -2.47 MPa and in service the section runs from 7.61 to 3.82 MPa — compression everywhere. The same beam with no prestress reaches -12.67 MPa at the bottom fibre, which is 4.2 times what the concrete can hold. Internal forces

The load put on backwards

Every other structure in this collection waits for its load and then resists it. A prestressed one is given a load first — chosen, permanent, and pointing the wrong way — so that when the real one arrives the two nearly cancel and the material never has to do the thing it is bad at.

The middle third, computed. The kern of a 400 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±66.7 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows. Sections and stress

The middle third

A material that cannot be pulled imposes a condition on where the load may land, and the condition is a region rather than a point. For a rectangle it is the famous middle third; for every other section it is a shape nobody quotes, and one ordinary section's is nearly twice as generous as the rule allows.

The ground pushes back hardest where the beam has gone down furthest. A strip 16.4 m long and 1 m wide on ground of subgrade modulus 50 × 10³ kN/m³, carrying 1000 kN at its centre. The beam settles 3.90 mm under the load and the ground pushes back in proportion — the arrows are k times the settlement above them, peaking at 195 kN per metre — so the pressure diagram is the settlement bowl and not an assumed distribution. The characteristic length 1/β is 2.56 m: the bowl crosses zero at 6.04 m, which is 3π/4 of it, and beyond that the arrows reverse because the beam has lifted off. By 8.05 m — one π/β — the disturbance is 4.3% of what it was, which is why the moment 641 kNm and the peak pressure 195 kN/m contain no length at all. The settlement is drawn 217 times full size — the real bowl is 3.90 mm deep over 16.4 m, about 1 in 4207 — and at true scale the beam would be a straight line. Internal forces

The beam that sits on the ground

Every other beam in this collection is held at points. A footing is held everywhere, by something that pushes back in proportion to how far it is pushed — and that single change hands the structure a length it did not choose. Two or three of those lengths from the column, nothing knows the load happened.

Four inequalities, and the wedge between them. The Magnel diagram: every limit on a prestressed section, plotted as a bound on 1/P against the eccentricity. Two of the four come from transfer, when the force is largest and the only moment is the beam's own weight, and two from service, when 20% of the force has been lost and the moment is 640 kNm. Each is linear in 1/P, which is the substitution that makes the problem a picture rather than a search. The shaded region is every force-and-eccentricity pair the section will accept: it is a wedge opening to the right, so the cheapest prestress is always at the largest eccentricity the cover allows — 1029 kN at e = 400 mm here. The section's kern is 241 mm, and every useful answer is outside it. Sections and stress

Four inequalities and a wedge

A prestressed section has to satisfy two stress limits when the force is largest and the load smallest, and two more when the force has relaxed and the load has arrived. Each is linear in one over the force — which turns a search for a prestress into a region on a page, and turns an impossible section into an empty one.

The line, and the stone it has to stay inside. A masonry pier 9 m high, 1.6 m thick at the top and battered 12% on its outer face, taking a thrust of 40 kN per metre of run at 25° to the horizontal. The line drawn through it is the locus of the resultant on each horizontal cut: everything above the cut is the free body, and the resultant's position is the moment divided by the vertical force. The dashed pair is the middle third, inside which no tension is implied anywhere on the joint. The line stays inside the stone throughout and reaches the base at 0.503 m from the centre, against a half-width of 1.34 m — but outside the middle third, so part of the base joint is open and the toe is carrying a triangle. Nothing about the strength of the masonry appears anywhere in this figure, and that is the point. Structural form

The weight that makes it safer

Every load in this collection makes a structure worse. A pinnacle does not. A masonry pier fails when the line of compression leaves the stonework, and adding weight at the top rotates that line back towards the vertical without adding anything the pier cannot carry — so the stone is not being strengthened, it is being aimed.

A straight line, and the comfortable case is already two thirds down it. The capacity of a 215 mm masonry wall as a fraction of its squash load, against the eccentricity of the resultant. Nothing in this figure is a buckling calculation. A material that cannot be pulled bears on a strip of width 3(t/2 − e) under a triangular stress block, so the capacity is exactly 1.5f(t − 2e) — a straight line, zero when the resultant reaches the face, and already at 67% at the edge of the kern. The middle third is treated everywhere as the comfortable case; a wall loaded there has given away a third of its capacity before slenderness has been mentioned. The lower line is the same wall with slenderness in it, which enters as an ADDITIONAL eccentricity of 17.4 mm rather than as a reduced stress — h_ef²/2400t, for h_ef = 3000 mm. Euler's load for this wall is 9.6 times what the eccentricity rule allows, which is why no masonry calculation contains it. Stability

It does not buckle, it runs out of width

Every stability failure in this collection is a member that could have carried tension deciding to go sideways instead. Masonry cannot carry tension, and its failure under an eccentric load is not a bifurcation at all — the bearing area simply shrinks until it runs out. The capacity is exactly linear in the eccentricity, Euler's load is ten times anything allowed, and no material property appears until the very end.

The middle third, computed. The kern of a 300 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±50.0 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows. Materials

The strength thrown away on purpose

Masonry, concrete and soil are all analysed as though they had no tensile strength whatever. Each of them has some. The decision to set it to zero is the single most consequential modelling assumption in the subject, it is safe for one kind of check and unsafe for another, and almost nothing that uses it says which.

The library, page 3 of 7 — where kern-zone sits