The middle third, computed
The middle third, computed. The kern of a 400 × 600 mm rectangle, computed by asking, for every direction, how far the resultant can move before the far face would be pulled. It reaches ±100.0 mm vertically and ±66.7 mm horizontally, which are h/6 and b/6 exactly, and the region between is a rhombus rather than the ellipse the two numbers suggest — a resultant on a diagonal has less room than either axis allows.
8 essays call
kern-zone. The drawing above is what it returns with no arguments at all; every
call below passes it something, because a placement that passes nothing draws whichever
member of the family the generator happens to default to rather than the one its essay
argues about.
Where it is called
Changing this generator changes every one of these figures.
Weight is the only thing resisting it
A structure that is strong enough everywhere can still be blown over, and nothing in its material properties has any part in whether it is. The whole answer is a weight and a width — and the failure begins long before anything tips, at the moment one edge stops pressing down.
The load put on backwards
Every other structure in this collection waits for its load and then resists it. A prestressed one is given a load first — chosen, permanent, and pointing the wrong way — so that when the real one arrives the two nearly cancel and the material never has to do the thing it is bad at.
The middle third
A material that cannot be pulled imposes a condition on where the load may land, and the condition is a region rather than a point. For a rectangle it is the famous middle third; for every other section it is a shape nobody quotes, and one ordinary section's is nearly twice as generous as the rule allows.
The beam that sits on the ground
Every other beam in this collection is held at points. A footing is held everywhere, by something that pushes back in proportion to how far it is pushed — and that single change hands the structure a length it did not choose. Two or three of those lengths from the column, nothing knows the load happened.
Four inequalities and a wedge
A prestressed section has to satisfy two stress limits when the force is largest and the load smallest, and two more when the force has relaxed and the load has arrived. Each is linear in one over the force — which turns a search for a prestress into a region on a page, and turns an impossible section into an empty one.
The weight that makes it safer
Every load in this collection makes a structure worse. A pinnacle does not. A masonry pier fails when the line of compression leaves the stonework, and adding weight at the top rotates that line back towards the vertical without adding anything the pier cannot carry — so the stone is not being strengthened, it is being aimed.
It does not buckle, it runs out of width
Every stability failure in this collection is a member that could have carried tension deciding to go sideways instead. Masonry cannot carry tension, and its failure under an eccentric load is not a bifurcation at all — the bearing area simply shrinks until it runs out. The capacity is exactly linear in the eccentricity, Euler's load is ten times anything allowed, and no material property appears until the very end.
The strength thrown away on purpose
Masonry, concrete and soil are all analysed as though they had no tensile strength whatever. Each of them has some. The decision to set it to zero is the single most consequential modelling assumption in the subject, it is safe for one kind of check and unsafe for another, and almost nothing that uses it says which.