Generator

The end-plate generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
How a moment crosses a gapA moment end plate with three bolt rows. The moment is carried as a couple: tension in the rows, compression through bearing at the bottom flange. The plastic distribution reaches 172.8 kN·m and the elastic one 142.29 kN·m, a factor of 1.21 — and the compression at the bottom flange is 540 kN either way, which is the check that gets forgotten because it is not a bolt.180 kNrow 1 · 420 mm180 kNrow 2 · 340 mm180 kNrow 3 · 200 mm540 kN compressionPlastic distribution — M = 172.8 kN·mthe other distribution is drawn faintly: 1.21× between them

4 essays call end-plate. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

100 kNe = 150centroidworst bolt 50.37 kNSix bolts · direct shear 16.67 kN eachelastic vector method Connections

The connection is not a point, and every diagram on this site says it is

Every free body drawn here has joined its members at points. Real structures fail at the joints far more often than in the members, and the reason is that a joint is exactly the region the theory behind every other page explicitly excludes.

100 kN appliedbolt 150.63 kNprying 50.63 kNm = 45n = 40flange 20 mm · one-hingebolt force is 1.51 times the applied load Connections

The force the bolt never saw applied

Pull a tee stub with a hundred kilonewtons and its bolt carries a hundred and fifty. The extra comes from the flange bending and pressing its own edge against the thing it is bolted to, and no free body of the connection as a point contains it.

00.0050.010.0150.020.0250.030.0350.040.0450.05050100150200rotation, radiansmoment, kN·mrigid abovepinned belowweb cleats — pinnedflush end plate — semi-rigidextended end plate — semi-rigid Connections

Neither pinned nor rigid, which is every real connection

Frame analysis offers two options for a joint and reality supplies a continuum between them. Worse, the boundaries are not properties of the connection at all — the same end plate is rigid on a short stiff beam and semi-rigid on a long slender one.

180 kNrow 1 · 420 mm180 kNrow 2 · 340 mm180 kNrow 3 · 200 mm540 kN compressionPlastic distribution — M = 172.8 kN·mthe other distribution is drawn faintly: 1.21× between them Connections

Making a moment cross a gap

A moment is not a thing that can be handed across a joint. It has to be turned into a pair of forces, carried separately, and reassembled — and the whole design is a question of how the tension is shared between bolt rows that are not equally able to take it.