Generator

The effective-length generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
The ends decide the length that mattersFour columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square.K = 0.5both ends fixedK = 0.7one fixed, one pinnedK = 1both ends pinnedK = 2fixed at the base, free at the topsame column, same section, four ways of holding the endsthe load at which each buckles goes as 1 ÷ K² — a factor of sixteen across this row

6 essays call effective-length. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

20H 10.0 M 22.2H 10.0 M 22.2the two base shears add to the applied 20 — the split came from stiffness, not staticsthe sway is exaggerated; a real frame at this load moves a fraction of a millimetre Structural form

The frame that leans, and what stops it

A rectangle of pinned bars folds flat. Make the corners rigid instead of adding a diagonal and it does not — which buys an unobstructed opening and costs bending in every member of it.

5010015020000.20.40.60.811.2slenderness (effective length ÷ radius of gyration)they cross at λ = 75squashingEuler bucklingreal columns, which are neither Stability

Strong enough and still falls over

A column can fail at a fraction of the load its material could carry, by going sideways. Buckling is a failure of stability rather than of strength, and it is decided by geometry.

K = 0.5both ends fixedK = 0.7one fixed, one pinnedK = 1both ends pinnedK = 2fixed at the base, free at the topsame column, same section, four ways of holding the endsthe load at which each buckles goes as 1 ÷ K² — a factor of sixteen across this row Stability

The ends decide the length that matters

Four columns of identical height and section, buckling at loads sixteen times apart. Nothing differs but what is holding the two ends.

00.20.40.60.80246810applied load ÷ buckling load1.1×1.3×1.4×2.0×3.3×10.0×first-order analysis says the answer is always 1×one over one minus the ratio Stability

The load that makes itself worse

A structure that has leaned carries its weight off the axis, which makes it lean further. The amplification is one over one minus the load ratio, and it runs away long before the buckling load.

2000400060008000100001200002004006008001000distance between lateral restraintsthey cross at 3803the plastic capacity of the sectionelastic critical momentSt Venant torsion alone — what is left at long lengthswarping dominates here Stability

The beam that fails sideways

A deep narrow beam bending in its strong plane can, at a moment well below its capacity, swing out of that plane and twist. The failure has nothing to do with how much it can carry and everything to do with what is holding it.

05010015020025001020304050brace stiffness (units of EI/L³)critical load (units of EI/L²)ideal stiffness ≈ 159 EI/L³21.839.5 — braced9.87 — unbraced Stability

The brace that need not be strong

A brace holding a column at mid-height carries almost no force. What it has to be is stiff — and the stiffness required is exact, large, and reached at a knee past which more buys nothing at all.

The whole library