Generator

The ends decide the length that matters — the effective length generator

Rendered here at the parameters it defaults to, with every essay that calls it — which is the same list as the blast radius of changing it.
The ends decide the length that matters. Four columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square.

The ends decide the length that matters. Four columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square.

14 essays call effective-length. The drawing above is what it returns with no arguments at all; every call below passes it something, because a placement that passes nothing draws whichever member of the family the generator happens to default to rather than the one its essay argues about.

Where it is called

Changing this generator changes every one of these figures.

A portal frame swaying under 20 kN. A portal frame pushed sideways, solved by the stiffness method because statics cannot divide the load between two columns. The base shears come out at 10.0 and 10.0 and add to the applied 20; the peak moment is 22.2. The sway is drawn hugely exaggerated, and the moment diagram is plotted on each member's tension face. Structural form

The frame that leans, and what stops it

A rectangle of pinned bars folds flat. Make the corners rigid instead of adding a diagonal and it does not — which buys an unobstructed opening and costs bending in every member of it.

The ends decide the length that matters. Four columns of identical height and section, buckling under four sets of end conditions. The effective length factor is the fraction of the column that behaves like a pin-ended one, and the buckling load goes as its inverse square. Stability

The ends decide the length that matters

Four columns of identical height and section, buckling at loads sixteen times apart. Nothing differs but what is holding the two ends.

The load that makes itself worse. The amplification of a deflection against the ratio of applied load to buckling load. A structure at half its buckling load deflects twice as far as first-order analysis predicts, and the curve runs away well before the load is reached. Stability

The load that makes itself worse

A structure that has leaned carries its weight off the axis, which makes it lean further. The amplification is one over one minus the load ratio, and it runs away long before the buckling load.

The length at which a beam stops being a beam. Elastic critical moment against the distance between lateral restraints, with the section's plastic capacity drawn across it. The two cross at 3803 — beyond that length the beam buckles sideways before it reaches the strength its cross-section has, and the capacity is set by the restraints rather than by the steel. Stability

The beam that fails sideways

A deep narrow beam bending in its strong plane can, at a moment well below its capacity, swing out of that plane and twist. The failure has nothing to do with how much it can carry and everything to do with what is holding it.

A brace is a stiffness requirement, not a strength one. Critical load against brace stiffness for a pinned column braced at mid-height. The curve climbs from the unbraced Euler load of 9.87EI/L² and flattens at 39.48EI/L², which is the Euler load of the braced segment — past that the column buckles in a shape the brace does not obstruct, and further stiffness buys nothing. The knee is at about 159EI/L³. A stiffness of 60EI/L³ is marked, reaching 21.75EI/L². Stability

The brace that need not be strong

A brace holding a column at mid-height carries almost no force. What it has to be is stiff — and the stiffness required is exact, large, and reached at a knee past which more buys nothing at all.

It moves, or it pushes. Never both, and never neither. A 30 m steel member 30 °C warmer than it was built, in three conditions. Free, it grows 10.8 mm and carries nothing. Held, it moves nothing and carries 75.6 MPa in compression — which is E·α·ΔT and contains neither the length nor the area of the member, so the identical stress arises in a two-metre strut. Held by a spring it does some of each: 3.2 mm of movement and 53.2 MPa, and the split is decided by the spring rather than by the member. Deflection

The movement nobody applied

A temperature change is the only load in this collection that a structure can decline. Let it move and it produces a movement with no stress; hold it and it produces a stress with no movement — and that stress contains no length, no area and no second moment, so a bracket and a bridge girder carry exactly the same one.

One restraint, and several times the load. The same portal — the same columns, the same beam, the same steel — buckling with its head held against sway and with its head free to sway. The braced frame's critical load is 16.46 EI/L² and the swaying one's is 5.69 EI/L², a factor of 2.89, and the effective length factor that comes out of each eigenvalue is 0.774 against 1.317. Both are eigenvalues of the assembled frame at a beam-to-column stiffness ratio of G = 1.00; the buckled shapes are the mode vectors themselves, drawn at 18 per cent of the storey height so that the movement can be seen. Stability

Held, and not held

One horizontal restraint at the head of a storey, carrying no vertical load whatever, moves the critical load of the columns beneath it by a factor of 2.89. Effective length is a property of the frame, not of the member.

How stiff a brace has to be before the frame stops swaying. The effective length factor of a swaying portal against the stiffness of a horizontal spring at its head. The curve starts at k = 1.317, the unbraced value, and falls to 0.774 — the factor for the same frame with its head held — at a brace stiffness of 23.2 EI/L³. Past that point the frame buckles in the non-sway mode, which the brace does not restrain, and further stiffness buys nothing at all. The threshold is worth stating as 1.41 N꜀ᵣ/L, which is the form the number is memorable in: for a storey carrying a thousand kilonewtons over four metres it is about 0.35 kN per millimetre of sway. Against the frame's own lateral stiffness of 12.0 EI/L³ it is a factor of 1.93. Stability

The most dangerous day is before it is finished

A structure is analysed once, complete, with every restraint present. It spends weeks in states nobody drew — a beam landed with no deck on it holds 17% of the moment its section is worth, a frame not yet braced buckles at a third of the load it will, and a bolt not yet tightened is a pin where the analysis assumed a fixity.

A column that has nothing on it but itself. A 30 m column carrying no load except its own weight, with its buckled shape and the axial force that produced it. The force is zero at the top and largest at the base, which is why the answer is not Euler's: the eigenvalue is a load intensity and comes out as q_cr L³/EI = 7.835, a number with no π in it, computed here as the smallest eigenvalue of the same stiffness and geometric-stiffness matrices that give a tip-loaded column its Euler load. It is equivalent to a tip load of 3.18 times as much total weight — a column carries its own weight better than it carries somebody else's, because most of the weight is near the base where the buckle is not. The height limit that follows is a cube root, so a section of radius of gyration 80 mm falls over on its own at 52 m and one of twice that reaches only 82. Stability

Too tall for nothing but itself

Every critical load on this site so far has been applied at the top of a column. A mast carries a load that is zero at the top and largest at the base, the governing equation stops being harmonic, and the answer comes out as a number with no π in it — along with a maximum height that is almost the same for steel, aluminium and wood.

The restraint chooses the buckling length, and it is not the member's. A compression flange 12 m long held sideways not at points but everywhere, by a restraint of 0.35 N/mm per mm of length. Unrestrained it would buckle at 173 kN in a single half-wave, drawn faintly. Restrained it buckles at 1968 kN — 11.4 times as much — in two half-waves, because the sum n²π²EI/L² + kL²/n²π² has its minimum there and every other n is worse. The effective length that answer implies is 3555 mm, which is 0.30 of the member and is a property of the restraint rather than of the span. Stability

Held everywhere, and it forgets its length

A brace at a point divides a member's buckling length. A restraint spread along the whole member does something else — the member chooses its own number of half-waves, and past a few of them the critical load stops depending on the length at all.

Effective length is a property of the storey. The effective length factor of the one column that resists sway, against the total gravity load on the storey as a multiple of its own. At the left-hand end it carries the storey alone and its K is 1.99 — the 2.0 every chart gives a column fixed at the base and free to sway at the top, reproduced here by a route that never mentions a chart. Then columns are added that have pinned bases and therefore no lateral stiffness whatever. They contribute load and nothing else, so they cannot buckle on their own and they lower the load at which everything buckles together. K rises as the square root of the load ratio, exactly, and at the storey drawn — three leaning columns carrying 69% of the gravity load — it is 3.57. That is off the end of every published alignment chart, and the leaning columns themselves, which a designer would take at K = 1.0 for pinned ends, are at 2.54. Stability

The column that leans on its neighbours

A column with a pinned base and a pinned top has no lateral stiffness at all and cannot stand up alone, and yet thousands of them do. What holds them is the rest of the storey, and what it costs is paid by whichever columns do have stiffness — whose effective length rises as the square root of the load being leaned on them, straight off the end of every chart.

A buckling load with no compression anywhere in the member. A tube of radius 81.6 mm and wall 5 mm under pure torque — no axial load at all — buckles into a helix at T = 2πEI/L, which for the section drawn is 1877 kNm. Two things are absent from that expression and both are surprising: the length appears to the first power rather than the second, and the shear modulus does not appear at all, so the torsional stiffness of the member has nothing to do with the torque at which it buckles in torsion. The comparison is the torque that yields the same tube, 42.9 kNm — a factor of 43.8 below it. The mode arrives first only past a length of 263 m, which is πE/τ_y = 3219 radii and contains no thickness whatever. Stability

The buckling load with no compression in it

Twist a straight bar hard enough and it snaps into a helix, with no axial load on it anywhere. The load at which that happens is 2πEI/L — first power of the length, and no shear modulus in it at all, so how stiff the bar is in torsion has nothing to do with the torque that buckles it in torsion.

The load being amplified is not the load doing the amplifying. The sway amplifier 1/(1 − ΣP/P_cr) against the storey's total gravity load, as columns are added that carry load and provide no lateral stiffness. The critical load of the storey is fixed at 8203 kN by the bracing that exists, and every leaning column moves the structure along the axis without changing it. At the storey drawn the amplifier is 1.57, so the second-order sway moment is 57% on top of the first-order one — and none of that 70% of the load which is causing it appears in any stability calculation done column by column. The storey stays stable across the whole of this axis. That is the practical reason a gravity-only column is drawn on the frame model rather than designed on its own: it is not being checked, it is being counted. Stability

Counted, not checked

A column with pinned ends and no bracing cannot buckle on its own, so nothing about it fails a stability check. It still carries load, and load with no stiffness attached lowers the buckling load of everything around it — which is why a gravity-only column is put on the frame model and never designed by itself.

A base plate, and when the bolts start working. A 550 × 450 mm plate carrying 900 kN and 140 kN·m, so the resultant sits 155.56 mm from the centre against a kern of 91.67 mm. The plate is in partial contact: bearing over 358.33 mm at a peak of 11.16 N/mm², with the holding-down bolts carrying 0 kN. The plate lifts at 82.5 kN·m and crushes at 192.95 kN·m, and the bolts are not needed until 247.5 kN·m. Stability

The pinned base that is not pinned

A column base drawn as a pin is a plate bearing on grout, and a plate in contact over its whole length resists rotation whether anybody wanted it to or not. The stiffness it delivers depends on the axial load, so the assumption is one a frame can leave and re-enter as its loads change.